Chapter 4: INSTALLATION
Operating manual DC6AT
Page 19 of 28
4.4 Connection
=M
+
-
Ready
7
8
9
10
11
12
13
14
15
16
17
1 2 3
X2
X1
X1
X1
4 5 6
- +
Controller enable
clockwise
Controller enable
counter-clockwise
Set value for speed
Reset
Sample wiring
Analogue set
value
Controller enable
clockwise
Controller enable
counter-clockwise
Reset
Sample wiring
Fixed set values
Selection fixed set value {
4.4.1 Voltage supply
X1-2: GND
X1-3: +Supply
4.4.2 Motor connection
X1-5: + Connection motor
X1-6: - Connection motor
4.4.3 Control connection
4.4.3.1 Digital input signals
Specification digital inputs:
HIGH =
+5,6 …+15 VDC
LOW =
-0,5 … +5,5 VDC
Input impedance Ri = 10k
Cycle time
10 ms
X1-13: Reset
Pos. flank = reset fault message
X1-14: Fixed speed _2
1
X1-15: Fixed speed _2
0
X1-16: Controller enable counter-clockwise rotation (CCR), HIGH = CCR active
X1-17: Controller enable clockwise rotation (CR), HIGH = CR active