OPERATION
The DC charger is fully automatic in operation. Once installed, no further user action is
required. The unit automatically switches on when a charging voltage is detected on the
input supply. When a charging source is not present, it switches to a low power sleep mode.
SPECIFICATIONS
Model range:
Input voltage
Input current
Output voltage
Model number,
with remote sense
Model number,
no remote sense
12V
12A
12V
91136
91126
12V
15A
12V
91141
91131
12V
12A
24V
91135
91125
12V
15A
24V
91140
91130
24V
12A
12V
91138
91128
24V
15A
12V
91143
91133
24V
12A
24V
91137
91127
24V
15A
24V
91142
91132
24V
15A
24V
90131
The line charger operates in a way which controls the input current, such that the maximum
possible power is always drawn from the power source, without overloading the input supply
cables & connectors. The output charging current is constrained by the ability of the source
to supply power. The maximum battery charging current is therefore determined by each
particular installation. The curves below show this dependency:
DC Charger User Manual, Part No. 13328 Issue 5
0
5
10
15
20
25
30
Output v oltage
0
5
10
15
20
25
30
35
O
u
tp
ut
c
ur
re
nt
-
a
m
ps
Input = 25 volts
Input = 20 volts
Input = 15 volts
Input = 10 volts
Line charger - output current vs output voltage
input voltage held constant
input current 15 amps