– Enterprise Managed Media Converter
FCN-3112 Series User Manual V1.0
6
2.5 DIP Switches
There is a bank of DIP switches located on the back panel of the device that helps users to
configure the device without the need to access the web management. There is also a reset
button on the front panel. Please refer to
Table 2.2
for the functionality of these features.
Pin NO. &
Button
Function
Off
On
1
TX Auto-Negotiation
Disable
Enable
2
Manual TX Data Rate 10M/100M
10M
100M
3
Manual TX Data Rate 1000M
10M or 100M
1000M
4
Flow Control
Disable
Enable
5
Fiber Auto-Negotiation
Force
Enable
6
Reserved
Always off!!!
7
Link Alarm
Disable
Enable
8
TP Configuration
From S/W
From DIP
Diag. Button
Press once for Loopback test. Press and hold for 10 seconds to restore factory
default setting.
Table 2.2