Use a torque wrench if in doubt. Check
that the indoor unit and outdoor unit
have the same model designation.
• The heat pump is not intended to be used
by persons (children or adults) with any
form of functional disorders, or by persons
who do not have sufficient experience or
knowledge on how to use it, unless they
have received instructions concerning the
use of the appliance from someone who
is responsible for their safety.
Keep children under supervision to make
sure they do not play with the heat pump.
• A damaged power cord must be replaced
by an authorised service centre, or other
qualified personnel, to ensure safe use.
• The heat pump uses environmentally-
friendly R410A refrigerant, which is
among the most energy-efficient on the
market. The compressor is inverter-
controlled, which produces a higher level
of efficiency.
• The system monitors the energy
requirement and the frequency converter
regulates the compressor speed for
optimum energy efficiency.
• The control system's microprocessor and
software ensure optimum operation
under all conditions.
• Vibration-damping mountings and
bushings ensure quiet operation.
• Status indicator lamps make it easy to
monitor the heat pump.
• The compressor has a soft-start function.
• After a power cut, the heat pump restarts
automatically with the former settings.
• Connect the heat pump to a separate
electrical circuit (230 VAC, 50 Hz) with a
10 A fuse, overvoltage protection and
residual current device. Only connect the
SAFETY INSTRUCTIONS
ELECTRICAL SAFETY
• New installations and the expansion of
existing systems must only be carried out
by authorised electrician. Persons with
sufficient knowledge may replace switches
and wall sockets, fit plugs, extension cords
and lamp sockets. Consult an authorised
electrician if in doubt. Incorrect
installation can result in fire and/or
electric shock.
GENERAL
• Connection to a water pipe system must
only be carried out by an authorised
plumbing engineer.
• Installation of refrigeration must be
carried out by an authorised technician.
Take into consideration the following
information.
• The installation requires the handling of
refrigerant and must in accordance with
legislation (F-gas regulation EU 517/2014)
be carried out by an accredited
refrigeration engineer.
• Refrigerant pipes must not be bent to a
radius of less than 15 cm.
• Do not connect the heat pump to the
mains until the pipes have been
connected, the system modules have
been connected together, and the system
has been filled with water and vented.
• The units are heavy and have sharp
edges. Use the correct lifting technique.
Wear safety glasses and safety gloves.
• Do not remove the plastic plugs on the
pipe ends until just before connecting the
pipes.
• Check and tighten the connections after
24 hours. The refrigerant connections
must be tightened to 18 Nm.
Содержание 416120
Страница 3: ...1 2 4 5 3 5 6 7 1 2 3 4 9 8 10 11 12 13 14 15 16 22 17 18 19 21 20...
Страница 5: ...8 50 C 11 12 13 14 15 SET TEMP Temp Max temp 9...
Страница 6: ...10 11 12 13 3 1 2...
Страница 7: ...14 15 1 2 3 4 1 2 3 4 6 5...
Страница 8: ...16 17 1 2 3 7 5 6 4 7 5 3 1 2 6 8 9 4...
Страница 9: ...10 8 4 6 5 1 2 3 9 7 11 12 18 19...
Страница 10: ...20 21 22...
Страница 11: ...28 29 30 23 24 25 26 27 T6 12 m 12 m T6 T6 T6...
Страница 12: ...31 32 33 34 Min 10 cm 37 35 36...
Страница 13: ...38 39 40...
Страница 22: ...SE 22 TEKNISKA DATA...
Страница 43: ...NO 43 TEKNISKE DATA...
Страница 64: ...PL 64 DANE TECHNICZNE...
Страница 86: ...EN 86 TECHNICAL DATA...