EN
91
PARAMETERS
Parameter
Significance
Range
Standard setting
0
Temperature drop for return water Th1 in tap water mode
1–10°C
5°C
1
Temperature drop for return water Th2 in heating mode
1–10°C
2°C
2
Temperature drop for return water Th3 in cooling mode
1–10°C
2°C
3
Operation as per heating curve
0-OFF, 1-ON
0
4
Choice of heating curve
1–15
7
5
Correction value for set point temperature as per heating curve
- 2, - 1, 0, 1, 2°C
0
6
Maximum water temperature in tank
70–90°C
75°C
7
Automatic temperature increase (hygiene mode)
0-NO; 1-YES
0
8
Outside temperature at which heating starts
-9–19°C
18°C
9
Outside temperature at which cooling starts
20–53°C
20°C
10
Activation temperature for frost protection for solar energy system
-9–10°C
5°C
11
Detection interval for auxiliary heater
15–90 min
15 min
12
Temperature drop for return water Th4 for solar energy system
3–15°C
5°C
13
Activation temperature for frost protection for water tank
5–10°C
8°C
14
Frost protection for solar energy system
0-NO; 1-YES
1
15
Maximum permitted temperature for water in solar energy system tank
50–70°C
60°C
16
Maximum permitted temperature for water in solar panel
100–120°C
115°C
17
Emergency stop temperature on overheating of solar energy system
120–130°C
120°C
Operating mode as per curve
Refers to parameters 3, 4 and 5.
• When operated as per heating curve (parameter 3 = 1) the
set point temperature is controlled in heating mode, hot tap
water mode + heating and hot tap water mode + auto as a
function of the actual outside temperature. Higher outside
temperatures result in lower set point temperatures in
heating mode, and vice versa.
• The highest possible set point temperature for heating is
50°C.
• Use parameter 4 to set the required heating curve. There are
a total of 15 curves.
• The diagrams indicate the highest set point temperature for
respective curves.
FIG. 6
FIG. 7
FIG. 8
• Parameter 5 is used to change the set point temperature set
as per the selected heating curve. The actual set point
temperature will then be the set point temperature as per
the heating curve + correction value from parameter 5.
Example
• Parameter 3 is set to 1, and operation as per heating curve is
activated. The set point temperature for heating is adjusted
as per the heating curve, as a function of the actual outside
temperature.
• Set parameter 4 (heating curve) to 9, set parameter 5
(correction value) to 2.
• Result
– When the outside temperature is -12°C the set point
temperature for heating is (50 + 2)°C.
– When the outside temperature is 0°C the set point
temperature for heating is (40 + 2)°C.
– When the outside temperature is 10°C the set point
temperature for heating is (32 + 2)°C.
Parameter setting
1. When the heat pump is in standby mode or working, press
SET and
M
for 5 seconds to check the parameter setting.
2. Press or to check the parameter values in sequence.
3. Press SET. The parameter value flashes. Press or to
increase or reduce the parameter value.
Содержание 416120
Страница 3: ...1 2 4 5 3 5 6 7 1 2 3 4 9 8 10 11 12 13 14 15 16 22 17 18 19 21 20...
Страница 5: ...8 50 C 11 12 13 14 15 SET TEMP Temp Max temp 9...
Страница 6: ...10 11 12 13 3 1 2...
Страница 7: ...14 15 1 2 3 4 1 2 3 4 6 5...
Страница 8: ...16 17 1 2 3 7 5 6 4 7 5 3 1 2 6 8 9 4...
Страница 9: ...10 8 4 6 5 1 2 3 9 7 11 12 18 19...
Страница 10: ...20 21 22...
Страница 11: ...28 29 30 23 24 25 26 27 T6 12 m 12 m T6 T6 T6...
Страница 12: ...31 32 33 34 Min 10 cm 37 35 36...
Страница 13: ...38 39 40...
Страница 22: ...SE 22 TEKNISKA DATA...
Страница 43: ...NO 43 TEKNISKE DATA...
Страница 64: ...PL 64 DANE TECHNICZNE...
Страница 86: ...EN 86 TECHNICAL DATA...