12
ERROR MESSAGE AND ERROR CORRECTION
Error message
Possible reason
Possible Solution
INPUT BATTERY
VOLTAGE ERROR
Input voltage
under 11,0 V or over 15,0 V
Check input power supply
adjust or change
NO BATTERY
No battery or broken battery connected when
pushing the start button
Check battery or battery connection
OUTPUT BATTERY
REVERSE POLARITY
Polarity of battery wrong
Check battery connection
red = + plus black = - minus
OUTPUT CIRCUIT
PROBLEM
Charger overloaded
Check battery connection, start again
CHECK THE BATT.
OPEN CIRCUIT
Battery connection opened during charging
Check battery connections
CHECK THE BATT.
OVER VOLTAGE
Battery voltage set to high
Check voltage/ cell setup
CHECK THE BATT.
LOW VOLTAGE
Battery voltage set to low,
battery broken
Check voltage/ cell setup
Check battery pack
CONTENTS SUPPLIED
1 x Charger
xBase Deluxe
1x Operating Instructions
DISCLAIMER
Information in these operating instructions can be changed without prior notice. ANSMANN ENERGY cannot accept liability for direct, indirect,
accidental or other claims or consequential damages originated by using this charger and information given in these operating instructions.
ANSMANN ENERGY GMBH
Industriestrasse 10
D-97959 Assamstadt / Germany
e-Mail: [email protected] • www.ansmann-energy.com
Technical details subject to change without prior notice. No liability accepted for typographical errors or omissions. 01/2007
1_manual_xbase_07-01.indd 12
1_manual_xbase_07-01.indd 12
11.01.2007 16:43:55 Uhr
11.01.2007 16:43:55 Uhr
Prozessfarbe Schwarz
Prozessfarbe Schwarz