INDEX
Function
Parameter
Action
AC Input
230 V 50 Hz
Normal function
DC Input
11 - 15 V DC
Normal function
under 11 V or over 15 V
Display: INPUT VOLTAGE ERROR
Connected with wrong polarity
no function
Charge sockets
After pushing the Button “ENTER / START / STOP“: no battery connected
Display: NO BATTERY
Charge sockets
After pushing the Button “ENTER / START / STOP“: Battery connected
with wrong polarity
Display: WRONG POLARITY
Charge current
NiCd / NiMH / LiIon / LiPo / Lead Acid 0,1 - 5,0 A ± 10%
max. 50 Watt
Display: Values will be displayed
Charge end voltage
LiIon 4,1 V / cell ± 1% • LiPo 4,2 V / cell ± 1%
Lead Acid 2,45 V / cell ± 1%
Charge finished
OPERATION
Connect the
xBase Deluxe
charger with the mains cable to a 230 V mains supply or with the crocodile clips to a 11-15V DC supply. Please take care to use
the right polarity: red = + plus, black = - minus. When the charger is connected in the right way you will get an audible signal and the display shows the charge
menu. If the display doesn’t show anything the power supply is not connected correctly. If the input voltage is <11V or > 15V the display shows ”INPUT VOLTAGE”.
Now connect the battery pack with a suitable cable to the charger (Banana sockets). Please take care to use the right polarity: red = + plus, black
= - minus. If the polarity of the battery is wrong the display shows “WRONG POLARITY”. If there is no battery connected and the Button “START” is
pushed the display shows “NO BATTERY”. For further adjustments please follow the attached Menu Navigation.
MENU
After you have connected the
xBase Deluxe
charger the right way you have to chose right battery type by pushing the button “BATT TYPE”. By
pushing the button “BATT TYPE” once the displayed battery type will start flashing. By pushing “BATT TYPE” again the display changes between the
battery types (NI=NiCd; NH=NiMH; LI=Li-Ion; LP=Li-Po; PB=Lead Acid). Flashing of the battery type display will stop when pushing another button or
after a short time if no button is pushed.
The last used configuration will be saved.