background image

3

FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY

BEFORE POWERING OR INSTALLING YOUR  ArcPar 100 !

Save it for future reference.

This device has left our premises in absolutely perfect condition. In order to maintain this condition and to 

ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning 

notes written in this manual.

The manufacturer will not accept liability for any resulting damages caused by the non-observance of this 

manual or any unauthorized modification to the device.

Please consider that damages caused by manual modifications to the device are not subject to warranty.

The  ArcPar 100 was designed for indoor use and it is intended for 

professional application only. It is not for household use.

1. Safety instructions

DANGEROUS  VOLTAGE  CONSTITUTING  A  RISK  OF  ELECTRIC  SHOCK  IS  PRESENT  WITHIN  THIS 

UNIT!

Make sure that the available voltage is not higher than stated on the rear panel of the fixture.

This fixture should be operated only from the type of power source indicated on the marking label. If you are 

not sure of the type of power supplied, consult your authorized distributor or local power company.

Always disconnect the fixture from AC power before cleaning, removing or installing the  fuses, or any part.

The power plug has to be accessible after installing the fixture. Do not overload wall outlets and extension cords 

as this canresult in fire or electric shock. 

Do not allow anything to rest on the power cord. Do not locate this fixture where the cord may be damaged by 

persons walking on it.

Make sure that the power cord is never crimped or damaged by sharp edges. Check the fixture and the power 

cord from time to time.

Refer servicing to qualified service personnel.

This fixture falls under protection class I. Therefore this fixture has to be connected to 

a mains socket outlet with a protective  earthing connection.

Do not connect this fixture  to a dimmer pack.

LED light emission. Risk of eye injury. Do not look into the beam at a distance of less 

than 2 meters from the front surface of the product. Do not view the light output with 

optical instruments or any device that may conncentrate the beam 

If the fixture has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on 

immediately. The arising condensation water might damage your device. Leave the device switched off until 

it has reached room temperature.

Do not shake the fixture. Avoid brute force when installing or operating the fixture.

This fixture was designed for indoor use only, do not expose this unit to rain or use near water.

When choosing the installation spot, please make sure that the fixture is not exposed to extreme heat, moisture 

Содержание ArcPar 100

Страница 1: ...Version 1 4 US...

Страница 2: ...map 15 5 Robin ArcPar 100 DMX chart 17 5 1 Virtual colour wheel colour mixing chart 20 5 2 LED zone order 24 6 Control menu Standard and Easy control mode 25 6 1 Addressing and master slave setting D...

Страница 3: ...ng the fuses or any part The power plug has to be accessible after installing the fixture Do not overload wall outlets and extension cords as this canresult in fire or electric shock Do not allow anyt...

Страница 4: ...en rigging derigging or servicing the fixtu re Do not block the front objective LEDs with any object when the fixture is under operation The fixture becomes very hot during operation Allow the fixture...

Страница 5: ...2 Fixture exterior view 4 DMX OUT 5 DMX IN 6 Fuse holder 7 Mains IN 8 Mains OUT 9 Display and control butto ns 10 Safety wire attachment poin t 1 Mounting holder 2 Tilt locks 3 Lens array...

Страница 6: ...about proper installation consult a qualified electrician Core EU Core US Connection Plug Terminal Marking Brown Black Live L Light blue White Neutral N Yellow Green Green Earth This device falls unde...

Страница 7: ...t the fixture from mains 2 Insert the screw 1 with the plastic washer 2 into diffuser 3 and secure it by means of the plastic washer 4 2 Insert the diffuser 3 into the ArcPar 100 and secure it by scre...

Страница 8: ...from mains 2 Screw the accessory frame adaptor 1 on the ArcPar 100 housing with the four screws M4x8 2 and unlock the spring lock 3 via pushing this spring lock as show red arrows on the picture 3 Ins...

Страница 9: ...Secure both accessories by moving the spring lock 3 up as shows the red arrow on the picture Note the barndoors can be rotated to desired position and secured in this position via the securing screw...

Страница 10: ...ide areas where persons may walk by or be seated IMPORTANT OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE including calculating working load limits installation material being used and periodic safety...

Страница 11: ...11 When installing fixtures side by side avoid illuminating one fixture with another 1 Clamp 2 Trust 3 Safety wire 4 Attachment point 5 Folded mounting yoke...

Страница 12: ...puts you need to use adapter cables Building a serial DMX chain Connect the DMX output of the first fixture in the DMX chain with the DMX input of the next fixture Always connect one output with the...

Страница 13: ...ected with the fixture NOTE when you disconnecting the DMX wireless module from the fixture press and hold lock 5 during get ting the wireless module out To link the fixture with DMX transmitter The f...

Страница 14: ...r programs Every slave runs its program according to the program number of the master E g if the master runs program number 3 all slaves run their programs number 3 Note if the option Play Master is s...

Страница 15: ...On Time Total Reset DMX In Powr 0 255 Dim F 0 255 Temp Current Highest High Res Sw Ver IC 1 IC 2 Pers DMX Pres Mode 1 Mode 7 Display Turn On Off T On Off Contrast 0 100 Backlight 0 100 C Cal M On Off...

Страница 16: ...1 All Pr Edit Prog 1 Step 1 Powr Prog 2 Prog 3 Step 40 F Tim 0 25 5 S Tim 0 25 5 COPY Prg En 1 40 Special RDM Low RDM Hight Wireless Stat Unlink Adjust DMX Val Powr 0 255 Dim F 0 255 Calib Cal Col Re...

Страница 17: ...proportional 2 2 1 1 0 255 Red Cyan 8 bit all zones Red LEDs saturation control 0 100 proportional 3 0 255 Red Cyan fine 16 bit all zones Fine red LEDs saturation control proportional 4 3 2 2 0 255 G...

Страница 18: ...e LEDs saturation control proportional 16 21 0 255 White 8 bit zone 2 If RGBW mode is selected White colour saturation control coarse 0 100 If CMY mode is selected No function proportional 17 22 0 255...

Страница 19: ...ntrol On channel Special Functions The following effects are controlled by sound Rainbow effect with fade time Rainbow effect Zone effect 1 Zone effect 2 Zone effect 3 Zone effect 4 Zone effect 5 Rand...

Страница 20: ...22 0 18 255 0 23 0 21 255 0 24 0 24 255 0 25 0 27 255 0 26 0 30 255 0 27 0 36 255 0 28 0 41 255 0 29 0 46 255 0 30 0 52 255 0 31 0 58 255 0 32 0 64 255 0 33 0 68 255 0 34 0 74 255 0 35 0 80 255 0 36...

Страница 21: ...4 0 81 0 255 58 0 82 0 255 52 0 83 0 255 46 0 84 0 255 41 0 82 0 255 36 0 86 0 255 30 0 87 0 255 27 0 88 0 255 24 0 89 0 255 21 0 90 0 255 18 0 91 0 255 15 0 92 0 255 12 0 93 0 255 9 0 94 0 255 6 0 95...

Страница 22: ...255 246 0 0 137 255 237 0 0 138 255 228 0 0 139 255 219 0 0 140 255 210 0 0 141 255 201 0 0 142 255 192 0 0 143 255 183 0 0 144 255 174 0 0 145 255 165 0 0 146 255 156 0 0 147 255 147 0 0 148 255 138...

Страница 23: ...0 68 0 193 255 0 74 0 194 255 0 80 0 195 255 0 86 0 196 255 0 92 0 197 255 0 98 0 198 255 0 104 0 199 255 0 110 0 200 255 0 119 0 201 255 0 129 0 202 255 0 138 0 203 255 0 147 0 204 255 0 156 0 205 25...

Страница 24: ...1 110 0 255 0 232 104 0 255 0 233 98 0 255 0 234 91 0 255 0 235 84 0 255 0 236 77 0 255 0 237 70 0 255 0 238 63 0 255 0 239 56 0 255 0 240 49 0 255 0 241 42 0 255 0 242 35 0 255 0 243 28 0 255 0 244 2...

Страница 25: ...xture on the display shows adjusted dimmer intensity and colour before switching the ArcPar 100 off When the fixture is switched off both adjusted color and light intensity are saved into memory to us...

Страница 26: ...er to 0 press and hold both NEXT and PREV buttons and the Enter button at the same time DMX In DMX readout The menu is used to read DMX values of each channel received by the fixture Temp Temperature...

Страница 27: ...controller which will show you some possibilities of using the ArcPar 100 6 6 Stand alone St Alone The ArcPar 100 offers seven built in programs Prog 4 Prog 9 and All and three user editable programs...

Страница 28: ...nk fixture from wireless DMX Adjust Adjustment The menu allows the fine adjustment of effects DMX Val DMX values Use the menu to set DMX values of fixture s channels Calib calibration of white colour...

Страница 29: ...Universal Interface if the USB port is used If the connection is OK click on the Start Uploading button to start uploading It will take several minutes to perform software update If the option Increm...

Страница 30: ...ion 200W 230V I 0 87A power factor 0 97 Optic Light source 12 Osram Ostar RGBW multichips 3 zones with individual colour control of each Min LED life expectancy 60 000 hours RGBW colour mixing CTO Bea...

Страница 31: ...DMX 512 1986 1990 and 512 A Full DMX fidelity and frame integrity Auto sensing of DMX frame rate and frame size 5ms DMX latency Operational frequency range of 2402 2480 MHz Producer LumenRadio Connect...

Страница 32: ...ite 1 piece P N 10980217 Diffuser 10 for Parfect 100 white 1 piece P N 10980216 Diffuser 40 for Parfect 100 white 6 pieces P N 10980214 Diffuser 20 for Parfect 100 white 6 pieces P N 10980218 Diffuser...

Страница 33: ...output very quickly The cooling fan should be cleaned according to the situation at least annually The interior of the base should be cleaned at least annually using a vacuum cleaner or an air jet Mo...

Страница 34: ...l Version of the manual Date of issue Description of changes 1 1 29 05 2014 DMX chart added mode 6 RGBW 1 2 05 01 2015 Easy control mode added 1 3 14 10 2015 DMX chart added mode 7 1 4 06 05 2016 Sile...

Страница 35: ...35...

Страница 36: ...36...

Страница 37: ...37...

Страница 38: ...38...

Отзывы: