![Animo OptiFresh NG 2.0 2016 Скачать руководство пользователя страница 88](http://html.mh-extra.com/html/animo/optifresh-ng-2-0-2016/optifresh-ng-2-0-2016_service-book_2943863088.webp)
88
2016/01 Rev. 0.0
OptiFresh (Bean) NG 2.0
9.1.3 Main circuit board communication
The machine has standardized vending machine con-
nections for connecting coin mechanism, coin changer
or cashless payment systems.
These connectors meet the MDB protocol for vending
machines.
For further information or advice please contact our
support department.
Communication
Conn
Protocol
Notes
G13
Parallel interface
art. no. 04025 03267
- Coin acceptor NRI G13
- External release contact*
*the machine can be released by using a potential-free
contact (pulse).
- G13 Kabel 1 meter art. no. 03392
- Extern vrijgave contact; kabel 1004237
MDB
Serial interface
MDB (Multi Drop Bus)
art. no. 03433
- Coin changer NRI C
2
- Cashless payment system
- Telemetry EVA DTS (SD card needed)
Memory Card
Memory Card
- MDB cable 1 meter art. no. 03479
- MDB cable 1 meter art. no. 1004564 (2x male connector)
- MDB Y-kabel art.no. 1002008
RS232-2 Serieel interface
DEX UCS
new from sept 2015
- Telemetry EVA DTS / DEX UCS (SD card needed)
Memory Card
Memory Card
RS232
not used
G13
MDB
COMMUNICATION
RS232
RS232-2
CSI