57
2016/01 Rev. 0.0
OptiFresh (Bean) NG 2.0
EN
Service menu continued ...
Main item
Sub-item
Item
Range Set
Description
2.4 Settings
(continued...)
I/0 reset counters
yes-no
no
Add menu item Reset counters to the
operator menu.
I/0 Quick recipe
yes-no
no
Menu item Snelrecept aan het opera-
tormenu toevoegen
Drip tray signal
yes-no
yes
Deactivate the drip tray sensor warn-
ing in the software.
Demo modus
yes-no
yes
This function can be used when the
machine is in a showroom or at a
trade fair. The machine does not then
need to be connected to a water sup-
ply. In the display, DEMO is shown
on the bottom line. Keys, LEDs and
the Display operate normally.
Stop button
yes-no
yes
If this function is standard set to yes.
To deactivate the stop button, set no
Direct choice
yes-no
no
If this function is set to Yes, the
chosen product will be started im-
mediately, without the start key being
pressed.
Strength setting is possible.
Free vend
yes-no
yes
Set the machine for free or paid
vending.
I/0 Free vend
yes-no
yes
Add/remove menu item 1.0 Free
vend to the operator menu.
Cup sensors
Cup sensor left
yes - no
yes
yes; cup sensor active
no; cup sensor inactive
Cup sensor middle
yes - no
yes
Cup sensor right
yes - no
yes
I/0 Cup sensors
yes - no
yes
Add/remove menu item 1.10 Cup
sensors to the operator menu.
Optilight brewing
process
blink during process
yes - no
no
Blinking OptiLight during dispensing
a drink
blink rate
0,1 - 10,0
0,3
blinking rate setting
Optilight
R G B
red
coulour setting during blinking
Telemetry
None
No telemetry system connected.
MDB
Memory Card
Memory Card
Telemetry system connected via
MBD port. Insert SD card with min.
1Gb in card holder, here the EVA
DTS file will be stored. Data transfer
via MDB connection.
DEX-UCS
Memory Card
Memory Card
Telemetry system connected via DEX
port. Insert SD card with min. 1Gb in
card holder, here the EVA DTS file
will be stored. Data transfer via DEX
connection.