59
2016/01 Rev. 0.0
OptiFresh (Bean) NG 2.0
EN
Service menu continued ...
Main item
Sub-item
Sub
Range
Description
2.7 Hardware test
Inputs
Temperature
Boiler temp
Shows the status of the sensors/switches
concerned.
1
2
3
4
5
6
7
8
9
10
11
12
13 14 15
17
18
1
2
3
4
5
16
Level sensors
High Yes/no
Low Yes/no
Drip tray sensor
Yes/no
Waste bin
Yes/no
Door switch 1
Yes/no
Brewer switch
Yes/no
Key switch
Yes/no
Door switch 2
Yes/no
Key panel
Service panel
Outputs
Test by holding
in recipe button
11.
# During test the
display shows
the Nominal
current (mA).
When the
Nominal
current of a out-
put rises above
the set current *
mentioned output
will be shut off.
KW1
2500mA
Inlet valve (Boiler)
DV1
Dispenser valve 1 (Brewer)
DV2
Dispenser valve 2 (Mixer 2)
DV3
Dispenser valve 3 (Mixer 3)
DV4
Dispenser valve 4 (Hot water)
DV5
Dispenser valve 5 (n/a)
DV6
Inlet valve 6 (n/a)
IM1 #
600mA
Grinder motor 1 (Canister 1)
IM2 #
Ingredients motor 2 (Canister 2)
IM3 #
Ingredients motor 3 (Canister 3)
IM4 #
Ingredients motor 4 (Canister 4)
IM5 #
Ingredients motor 5 (Canister 5)
IM6 #
Ingredients motor 6 (Canister 6)
BM #
1500mA
Brewer motor
MM2 #
3000mA
Mixer motor 2
MM3 #
Mixer motor 3
Ventilator
-
Ventilator
LED’s
-
LED’s
KW3
-
Inlet valve (Optional Cold water)
OptiLight
red
green
blue