92
OptiBean (XL) Touch
2018/02 Rev. 0.4
Activities
Time
Consumables
Art.no.
OptiBean
Boiler 2-2
10 min
Change filter cartridge
- In case a water filter is installed, replace the
cartridge for a new one.
- Reset the 2.6 Service boiler signal in the
service menu.
Grinder
10 min.
Empty the grinder. Fill with two caps of coffee
grinder cleaner, hold a drip tray under the
outlet and run the grinder until it is empty.
GRINDZ™
1000151
Brewer
20 min.
Clean the brewer.
Check for correct operation.
Build in the replacement kit 25,000 cups.
Reset the service brewer signal in the service
menu.
2.13 Additional settings / 2.13.4
Reset service brewer
.
Standard
brewer
1004917
1x
1x
XL brewer
1004918
1x
1x
Carry out the cleaning procedure using
cleaning tablets.
1001397
Mixer(s)
10 min.
Check the motor shaft for dirt and wear.
Replace the mixer when it runs heavily or when the ball bearings are worn
out.
Replace the mixer blade.
1003569
1x