80
OptiBean (XL) Touch
2018/02 Rev. 0.4
5.1
Save settings
After installing and setting up (fine tuning) a machine, it
is possible to copy the most important settings to other
machines with
the same canister configuration
with an
SD/USB memory device.
Please write down each file name when the
display shows SAVE AS:
Please save the
Personal settings (.MDU) and
Recipes (.RCU)
only.
1. Place the SD/USB memory.
2. Navigate to ‘Save data’
3. Save the personal settings and the recipe settings:
SERVICE MENU
2.11 SD/USB MENU
2.11.01 SAVE DATA
2.11.01.00 PERSONAL SETTINGS
2.11.01.01 RECIPE
2.01
QUICK RECIPE PRO
2.02
RECIPE BUTTON SETTINGS
2.03
RECIPE SETTINGS
2.04 SETTINGS
2.05
RESET COUNTERS
2.06
SERVICE BOILER
2.07
HARDWARE TEST
2.08
READ LOG FILE
2.09
REMOVE LOG FILE
2.10
LOAD DEFAULTS VALUES
2.11
SD/USB MENU
2.12
CHANGE SERVICE PIN
2.13
OTHER SETTINGS
2.14 INSTALLATION
2.15 DESCALING
2.16
CLEANING MANAGEMENT
SERVICE MENU
2.11.01.00 PERSONAL SETTINGS
2.11.01.01 RECIPE
2.11.01.02 COUNTERS
2.11.01.03 LOG
2.11.01.04 OPERATING HOURS
2.11.01.05 CLEANING LOG
2.11.01.06 RINSING LOG
2.11.01.07 SAVE ALL
2.11.01 SAVE DATA
2.11.00 LOAD DATA / SOFTWARE UPDATE
2.11.01 SAVE DATA
2.11.02 LOGGING TO SD-CARD
2.11 SD/USB - MENU
2.11.00.00 PERSONAL SETTINGS
2.01.00.01 RECIPE
OK
2.11.00.00 PERSONAL SETTINGS
OK
2.01.00.01 RECIPE
SAVE AS:
3Bxxxx00.MDU
OK
SAVED
3Bxxxx00.MDU
SAVE AS:
3Bxxxx00.RCU
SAVED
3Bxxxx00.RCU
OK
4. Remove the SD/USB memory.