89
2018/02 Rev. 0.4
EN
OptiBean (XL) Touch
6.3
Periodic maintenance
6.3.1 Service boiler
During installation of the machine, the boilers service
moment has been set. See service menu item
2.06
Service boiler / 2.06.1 Service moment
During use, the drinks are counted. When the boiler
service moment is reached, the text [
Service Boiler
] will
appear on the display.
RINSING
WIENER MELANGE
CHOCOLATE MILK
CLEANING
WIENER MELANGE
CHOCOLATE MILK
SERVICE BOILER
WIENER MELANGE
CHOCOLATE MILK
SERVICE BREWER
WIENER MELANGE
CHOCOLATE MILK
1 Descale Boiler
Reaching the service boiler time is an indication that the
boiler needs to be descaled. Follow the instructions in
section
6.5 Descaling.
2 Replace water filter
If a water filter is used (advice), this is the signal to
replace the filter.
Reset the service boiler signal service in the
service menu after descaling or water filter
change:
2.06 SERVICE BOILER
│
└──
2.06.02 RESET SERVICE COUNTER
1
2