- 37 -
3354462_ATG_ut_GB
ENGLISH
GB
Alarm
Fault
Remedy
Notes
H2O
No water in chamber, or water
pressure too low.
Check that mains water is pre-
sen, if the problem persists in-
form the after-sales service.
Convection cooking cycles can
still be carried out
H2O.
No water at drain, or water
pressure too low
Check that mains water is pre-
sen, if the problem persists in-
form the after-sales service.
Convection and steam coo-
king cycles can still be carried
out
H2OL
There is no water in the cham-
ber or there is insuffi
cient wa-
ter pressure during washing.
Check that mains water is pre-
sent; if the problem persists in-
form the after-sales service.
Cooking cycles can be carried
out..
H2OL.
There is no drain water, or
there is insuffi
cient water pres-
sure during washing.
Check that mains water is pre-
sent; if the problem persists in-
form the after-sales service.
It is not possible to run cook-
ing cycles until an entire wash
cycle or emergency rinse has
been carried out.
E12
No mains gas, gas pressure too
low or fl ame detection failure.
Press RESET (the button may
have to be pressed several
times), if the problem persists
inform the after-sales service.
Stop cooking if this message is
repeated more than once.
OPE
Oven door opening or closure
request.
Open or close the oven door
Inform the after-sales service
if this message continues to be
displayed.
The cooking cycle does not
start until the door has been
opened or closed as required.
CLE
At oven switch-on:
Indicates
that cleaning is required.
Perform a washing program.
Normal operation of the oven
depends on the “Oven clean-
ing time limit OFF/ON” setting.
CAL
At oven switch-on:
Indicates
the need for the descaling op-
eration.
Perform descaling.
The oven’s functions are ena-
bled so cooking cycles can be
carried out.
E01
The cooking chamber probe
has failed or is not properly
connected.
Inform the after-sales service.
The oven’s functions are disa-
bled so no cooking cycles can
be carried out.
E02
The core probe has a failure
or has not been properly con-
nected.
Check the position of the pro-
duct core probe or inform the
after-sales service if it is faulty.
Cooking cycles with product
core probe cannot be carried
out.
E03
The steam discharge probe
has failed.
Inform the after-sales service.
Convection and steam coo-
king cycles can still be carried
out.
E04
The motor-operated valve is
not positioned correctly.
Switch on the oven again and
if the problem persists inform
the after-sales service.
Convection and steam coo-
king cycles can still be carried
out.
E05
Safety thermostat failure.
Inform the after-sales service.
The oven’s functions are disa-
bled so no cooking cycles can
be carried out.
E06
Overload cutouts tripped.
Inform the after-sales service.
The oven’s functions are disa-
bled so no cooking cycles can
be carried out.
E07
Power board failure
Inform the after-sales service.
The oven’s functions are disa-
bled so no cooking cycles can
be carried out
E08
The optional vacuum probe
has failed or is not properly
connected.
Press RESET.
Disconnect and reconnect the
vacuum probe before starting
the cooking cycle.
If the problem persists, call the
after-sales service.
E09
Maximum allowed temperatu-
re in chamber exceeded.
Inform the after-sales service.
The oven’s functions are disa-
bled so no cooking cycles can
be carried out.