Faults
Causes
Remedies
Smell of gas
Occasional leak because fl ame
has gone out.
Turn off the gas supply tap and
ventilate the room
The pilot light does not
ignite
The spark ignition devices are
not working.
Check that the ignition devices
are in good working order.
Light by hand with a naked
light.
Important
Contact the after-sales service.
Air in pipelines due to long
period out of use.
Make more attempts to light
the fl ame.
The pilot light goes out.
The thermocouple has not
warmed up enough.
Make more attempts to light
the fl ame.
The pilot light ignites but
the burner remains off .
Check the condition of the
thermostat and activate any
ignition enabling device.
The fl ame is yellow.
Burner dirty, heat exchange
pipes clogged, condensation
drips.
Important
Contact the after-sales service.
Burner control knob is stiff .
Gas control valve malfunction.
Important
Contact the after-sales service.
FAULT
TROUBLESHOOTING
The appliance has been tested before being put
into service.
The information provided below is intended to
assist in the identifi cation and correction of any
anomalies and malfunctions which might occur
during use.
The user can solve some of these problems him-
self, but for others specifi c technical knowledge
or skill is required, and so they must only be car-
ried out by qualifi ed staff with recognised experi-
ence acquired in the specifi c sector of operation.