CONVERSION OF THE GAS SUPPLY
The constructor has tested the appliance with i
ts own mains gas, identified by the sticker applied to
the nameplate.
If the type of gas to be connected is different from
that used for testing, proceed as follows.
1 - Turn off the gas supply tap (A).
2 - Change the burner nozzle (see page 15).
3 - Change the pilot light nozzle (see page 16).
4 - Adjust the minimum setting on the gas control
valve (see page 14).
5 - If necessary, replace the primary air bushing of
the burner (see page15)
6 - Remove the sticker from the nameplate and ap-
ply the new one to identify the gas being used.
Important
On completion of the operation, make sure
that there are no gas leaks or malfunc-
tions.If converting from Natural Gas to Uni-
versal LPG make sure the natural Gas
Regulator is removed.
TESTING OF THE APPLIANCE
Important
Before it is put into service, the system
must be tested to check the operating con-
ditions of every single component and iden-
tify any malfunctions. In this stage, it is
important to check that all health and safety
requirements have been complied with in
full.
To test the system, make the following checks:
1 - turn on the gas supply tap and check that the
connections are right;
2 - check that the mains gas is the same as that
used for commissioning of the appliance, and
carry out the conversion procedure if neces-
sary (see page 13);
3 - check that the burner is switching on correctly
and its combustion;check that the safety ther-
mocouple is working correctly;
4 - check that there are no gas leaks;
5 - check that the nameplates specify the correct
gas for the country of use.
IDM-3960330960.tif
A
A
Always install a quick-closing ON/OFF valve (A)
(not supplied). For Natural Gas equipment, fit the
gas regulator (B) supplied with the appliance to
gas connection.
Caution - warning
For natural gas equipment this appliance
must be fitted with a Bromic Oara 98 gas regu-
lator (AGA Approval No.5862) supplied
with the appliance.Do not use any other
gas regulator.Ensure regulator is fitted
with respect to the gas flow marked on the
housing of the regulator.
B