INSTALLATION OF THE APPLIANCE
All installation stages must be considered right
from production of the general layout. Before
starting these stages, as well as deciding the place
of installation, if necessary, the person authorised
to carry out these operations must organise a
"safety plan" to protect the people directly in-
volved, and he must also ensure strict compliance
with all legal requirements, especially those relat-
ing to mobile work-sites.
The place of installation must have all the connec-
tions needed to supply the appliance and dispose of
the production residues, must be suitably lit and
must meet all legal health and hygiene requiremen-
ts to prevent the contamination of the foods.
If necessary, fix the exact position of each individual
appliance or subassembly by mark coordinates to
locate them correctly.
Always leave a minimum clearance of 5cm from the
rear of the appliance to the wall except if the wall,
the internal structure and its coating is non-combu-
stible.If any internal part of the wall is made from a
combustible material, leave a 5cm gap regardless of
the external cladding on the wall.
ASSEMBLING APPLIANCES IN BANKS
To assemble appliances in banks (side by
side) proceed as described below.
1 - Remove the control panels.
2 - Apply masking tape to the edges to be placed
side by side.
3 - Apply food-approved sealant to the edges to be
placed side by side.
4 - Place the appliances side by side
5 - Connect the appliances with the fixing devices.
6 - Remove the excess sealant and the masking
tape.
7 - Apply the sealant to the inside of the lid (A), and
fit it to cover the fixing zone.
GAS CONNECTION
To make the connection, connect the mains line to
the appliance's connection pipe, fitting a shut-off
tap (A), to allow the gas supply to be cut off when
necessary.
Important
The tap (A), not supplied with the appliance,
must be installed in an easily accessible
position and its status (on or off) must be
obvious at a glance.This appliance shall be
installed only by authorised personnel and
in accordance with the manufacturer’s in-
stallation instructions, local gas fitting reg-
ulations, municipal building codes, water
supply regulations, electrical wiring regula-
tions, AS 5601/AG 601-Gas Installations
and other statutory regulations.