Instillation Instructions

 

(all electrical & plumbing should be done in accordance to all local codes)

 

 

Your  new  Iron  Blaster™ 

allows  for  simple  installation  and 

start 

up.   Installation  diagrams  are  provided to assist  you.   

Use    of  these  diagrams  and  the  following  procedures  will 

ensure  that 

the system is properly installed. 

 

Follow all state and local plumbing  and electrical  codes!

 

•    Do not use  vaseline, oils,  other hydrocarbon lubricants 
or 

spray silicone anywhere.  A silicon lubricant  may be used 

on  black  o

rings  but is  not necessary.    

avoid  any 

type

 

of  lubricants,  including  silicone,  on  red  or  clear  lip

 

seals.

 

 

•  Do  not  use  pipe  dope  or  other  sealants  on  threads.   

Only  teflon  tape  may  be  used    on  threads.        Teflon  

tape  is  not 

necessary on the nut connection or caps because of radial 

o

ring seals. 

 

•   The  pipe   size for  the  drain  line  should be  a  minimum 

of  3/4”.     Backwash flow  rates in  excess of  10  gpm   or 
length in  excess of  20’ require  1”  drain  line.

 

 

1.    Place   the filter where you want to install  it,  making sure 

it is  on a  clean,  level  and firm base. 

2.    Do  all  necessary plumbing  (Install  check  valve  on inlet 

to  filter,  inlet  to  inlet,  outlet  to  outlet  and  drain  line  to 

drain).  The    control  valve,    fittings  and/or  bypass    are  

designed 

to 

accommodate 

minor 

plumbing 

misalignments  but are  not designed to support  the weight 

of a system or the plumbing. 

3.      When  assembling  the  installation  fitting  package  (inlet 

and outlet), connect the fitting to the plumbing system  first 

and then attach the nut, split ring and o

ring.  Heat  from 

solder

ing  or  solvent  cements  may  damage  the  nut, 

split  ring  or  o

ring.    Solder    joints  should  be  cool  and 

solvent  cements  should  be  set  before  installing  the nut, 

split ring and o

ring. 

Avoid getting primer and solvent cement on any part of 

the o

rings,  split rings,  bypass  valve  or control valve. 

4.   a jumper ground wire should be installed between the 

inlet  and  outlet  pipe  whenever  the  metallic  continuity 
of  a  water  distribution  piping  system  is  interrupted. 
Install grounding  strap on metal pipes.

 

5.    The  drain connection may be made using either 5/8” poly

tube with nut &  insert  (see   page  23,  figure  17)  or  a 
3/4” 

female  adapter.  If soldering,  joints near  the drain must be 

done prior to connecting the drain  line flow control fitting. 

Leave  at least  6” between the drain line control fitting and 

solder   joints when soldering pipes that are  connected on 

the drain line control fitting.  Failure  to do this could cause 

interior damage to the drain line flow control fitting. 

6.   When installing a filter system it is common to provide filtered 

water to some fixtures such as  the kitchen cold faucet.  This 

is typically done as  a matter of personal preference.  In rare 

occasions  it has  been noted that the customer may experi

enc some air in the filtered water line on the morning after 

regeneration.   It has  proven to be beneficial  to plumb the 

line  for filtered

only water  fixture  in a  downward direction 

before the inlet to the softener (12  inches  recommended), 

then make a reverse  turn and go upward toward the fixture. 

Understanding that air  always  rises  to the highest point in 

a water system. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

 
 
 

When  installing  an  Iron Blaster™ Filter system it is  common to  provide  filtered  only  water  to  some fixtures  such as  the  kitchen  cold 
faucet.  This  is  typically  done as  a  matter of personal preference.  On  rare  occasions, the  customer may  experience some air in the 
filtered  water  line  the  morning   after  regeneration.   It has   proven  beneficial to  plumb   the  line  for  the  filtered  only  water   fixture  in a 
downward direction from  the  inlet  of  the  softener (12 inches recommended), then  make  a  reverse turn  and  go  upward toward the 
fixture.   Any accumulated air always  rises  to  the  highest point  in a  water  system and  cannot naturally  flow downward. 

  

Содержание PurAzone A03

Страница 1: ...PurAzone A03 Filtration PurAzone A03 Filtration Filter Manual Owner s Filter Manual 2013 2014...

Страница 2: ...that you need professional assistance for servicing your water filter please contact the dealer who installed this system Table OF Contents Job Specification Sheet Page 3 General Specifications 3 Pre...

Страница 3: ...se Bib Front Hose Bib Kitchen Cold Toilets All Cold Other INSTALLATION DATE SERIAL NUMBER NOTES Operating Pressures General Specifications Minimum Maximum 30 psi 120 psi Operating Temperatures Minimum...

Страница 4: ...onnected per local codes Surge protection is recommended with all electrical controls existing Plumbing Condition of existing plumbing must be free from lime and iron build up Piping that is built up...

Страница 5: ...5 Figure 2 Figure 4...

Страница 6: ...ings bypass valve or control valve 4 a jumper ground wire should be installed between the inlet and outlet pipe whenever the metallic continuity of a water distribution piping system is interrupted In...

Страница 7: ...ls vary depending on barometric pressure Manganese Limit 1 0 ppm amounts present over 1 0 ppm may gradually prevent iron removal Note For optimum manganese reduction pH should be greater than 8 5 Orga...

Страница 8: ...7 Iron Blaster 10 Iron blaster 12 Iron blaster 13 10 x54 12 x52 13 x54 1 0 1 6 2 35 1 1 1 4 6 7 5 3 7 5 10 1 Water temps above 60 F will require a higher backwash rate Consult factory...

Страница 9: ...ugh a regeneration cycle Capacity remaining is the number of gallons that will flashes in upper left corner of display between rotating display when RE GEN button pushed once GPM Flashes when the turb...

Страница 10: ...r three seconds The system will begin to regenerate immediately The request cannot be cancelled You must cycle all the way through the cycles to make it stop PLEASE NOTE This will reset the meter rege...

Страница 11: ...ween regenerations If value set to oFF regeneration initiation is based solely on gallons used If value is set as a number allowable range from 1 to 28 a regeneration initiation will be called for on...

Страница 12: ...XT to go to Step 6S Press REGEN to return to the previous step STEP 6 S Set Gallons Capacity using or button If value is set to oFF regeneration will be based solely on the day override set see Instal...

Страница 13: ...t be shown Factory setting OFF Press NEXT to go to step 21S or other selection screens for relay settings RELAY 1 SET POINT STEP 9S STEP 9 S If off was selected in previous step this screen does not a...

Страница 14: ...13 NEXT to go to Step 15S...

Страница 15: ...that amount Range 20 to 500 minutes REGEN is also an option for lockout Relay initiates 2 minutes prior to regen and completes 1 minute after regen Access REGEN setting by pushing down arrow through a...

Страница 16: ...o to Step 3D Press REGEN to exit Diagnostics SINCE LAST REGEN 342 GAL RESERVE HISTORY STEP 3D STEP 4D STEP 3D Volume since last regeneration This display shows gallons of water that has been treated s...

Страница 17: ...ess and simultaneously for three seconds and release then press and simultaneously and release If screen in step 2VH does not appear in 5 seconds the lock on the valve is activated TOTAL DAYS 970 STeP...

Страница 18: ...17 RETURN TO NORMAL MODE...

Страница 19: ...CS OFF Factory Setting is OFF Press NEXT to go to Step 10CS alTernaTOr SYSTeM STeP 4cS STeP 4cS Twin alternating System Allows automatic alternation between two units to provide SeT alT a filtered wat...

Страница 20: ...16 NEXT to go to Step 10CS...

Страница 21: ...Step 11CS STeP 8cS Configuring the Control Valve for Water Reclamation Mode Select Reclama tion Enabled for control operation Motorized Alternating Valve will advance to Bypass at a set time after the...

Страница 22: ...REGEN If the dP switch is closed a regeneration will be prevented from occurring OFF Factory setting is off Press NEXT to go to Step 14CS Press REGEN to return to previous step bacKWaSH SeT cYcle 1 rI...

Страница 23: ...tached to board if not replace transformer Error Code 103 Motor ran too long C1 High drive forces on piston C1 Loosen drive cap gear 1 4 turn timed out trying to reach next position C2 Address high dr...

Страница 24: ...20 place If not replace stack assembly B2 Mechanical Binding B2 Drive gear and reducing gears should spin freely replace if necessary...

Страница 25: ...C D E Power outages Time of day not set correctly Time of regeneration incorrect Control valve set at on 0 immediate regeneration Control valve set at NORMAL on 0 A B C D E Reset control valve to cor...

Страница 26: ...rror 106 107 or 116 117 occurs and the valve has not entered regeneration Ozone Generator Spare Replacement Parts Denotes recommended spare maintenance parts Followed by quantity per unit recommended...

Страница 27: ...ate Distributor Part of Vortech Tank 7 Bypass Valve 1 101325 8 Inline Check Valve Kit 1 104174 includes 90 vertical adapter inline check valve 9 Ozone Generator 1 110110 10 Check Valve 1 110239 11 Tan...

Страница 28: ...and plug back in This resets the electronics and establishes the service piston position The display should flash all wording then flash the software version ex 214 and then reset the valve to the se...

Страница 29: ...jector Screen Injector Plug and O Ring 1 2 3 4 5 The injector plug and the injector each contain one 011 lower and 013 upper o ring Note For upflow position injector is located in the up hole and inje...

Страница 30: ...019 1 6 102406 DLFC Retainer Assy 1 7 101591 101595 101598 101561 DLFC 5 3 gpm for 3 4 DLFC 7 5 gpm for 3 4 DLFC 9 0 gpm for 3 4 DLFC 10 0 gpm for 3 4 1 One DlFC must be used if 3 4 fitting is used D...

Страница 31: ...Ring 2 3 102165 O Ring 215 2 4 102450 Bypass 1 Rotor 2 5 V3146 Bypass Cap 2 6 V3147 Bypass Handle 2 7 109479 Bypass Rotor Seal Retainer 2 8 102159 O Ring 135 2 9 102161 O Ring 112 2 10 102160 O Ring 2...

Страница 32: ...cap Do not use a pipe wrench to tighten or loosen nuts or caps Do not place screwdriver in slots on caps and or tap with a hammer Do not use pipe dope or other sealants on threads Teflon tape must be...

Страница 33: ...der nO deScrIPTIOn QTY 1 102141 Nut 1 Quick Connect 2 2 102437 Split Ring 2 3 102165 O Ring 215 2 4 106769 Fitting 3 4 Brass Sharkbite 2 1 4 110135 Fitting 3 4 Brass Sharkbite Asy Set of 2 1 4 1 4 1 2...

Страница 34: ...28...

Отзывы: