1
−
Flow Control Valve
Be sure to observe warnings and cautions in this instruction manual.
If not, it can cause paint ejection and serious bodily injury by drawing organic solvent.
Be sure to observe following
marked items which are especially important.
Indicates a potentially hazardous situation which, if not avoided, may result in serious injury or loss of life.
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or
property damage.
Indicates notes which we ask you to observe. The safety precautions in this instruction manual are the
minimum necessary conditions. Follow national and local regulations regarding fire prevention, electricity
and safety as well as your own company regulations.
Important specifications
Max. Working Pressure
Fluid / IN ; 2.5MPa / 25bar / 360PSI Fluid / OUT ; 0.6MPa / 6bar / 87PSI Adj. Air ; 0.6MPa / 6bar / 87PSI
Max. Temperature
Atmosphere ; 5
℃〜
40
℃
Fluid / Air ; 5
℃〜
43
℃
Main specifications
Model
Material of
wet section
Pressure range
(secondary)
MPa (bar / PSI)
Max. primary
pressure
MPa (bar / PSI)
Max. air
pressure
MPa (bar / PSI)
Max. Flow
L/min (cfm)
Fluid & Air
connection
Mass
g (lbs)
FCV-3
Aluminium
0 ~ 0.6
(0 ~6 / 0 ~87)
2.5
(25 / 360)
0.6
(6 / 87)
2.0
( 0.07 )
Fluid inlet G3/8
Fluid outlet Rc1/4
Air tube
φ
6x
φ
4
550 (1.2)
FCV-3N
Stainless steel
720 (1.6)
How to connect and operate
When connecting joints to exhaust thread section
(
Fluid outlet Rc1/4
)
, apply median strength adhesive to thread section
or wind sealing tape around thread section to prevent liquid from leaking.
Pay attention that paint does not include dirt and foreign matter.
Using paint containing foreign matter can cause leakage from seated section and unstable fluid output.
Set so that primary side supply fluid pressure is higher than operating air pressure by over 0.05 Mpa
(
0.5bar
/
7.3PSI
)
.
If primary side supply fluid pressure is lower than operating air pressure, fluid output will become unstable.
This Anest-iwata Flow Control Valve complies to ATEX
regulations 94/9/EC,
Protection level
:
Ⅱ
2 G X
,
Suitable for use in Zones 1 and 2.
X marking
:
Any static electricity discharge from the flow control
valve is to be diverted to the grounded by connecting
to grounded pump or grounded fluid pipelines or
grounded metal bracket as stipulated.
This manual contains IMPORTANT WARNINGS and INSTRUCTIONS.
Equipment in this manual is exclusively for painting purposes.
Do not use for other purposes.
The operator shall be fully conversant with the requirements stated in this
instruction manual including important warnings, cautions and operation
and correct handling.
Read and understand the instruction manual, before use and retain for
reference.
FCV-3
・
FCV-3N
INSTRUCTION MANUAL