3.3.3 - Erase a number

 

 

Enter the sequence : « 

#

 » then, the memory number, then « 

#

 »

       

         

Example : Erase the number and memory 

101 

 

#  101  #

         Nota : 

If no key is pressed for over 20 seconds, the unit plays a «

BEEP

»  and  returns  to  the     

                    start of the memory selection part of the programming mode.

3.4 - Memory attribution

3.4.1 - Transfer method  

         

The BOX-C may be programmed to interface with the call center, utilizing the available software and     

         specifications.

         

To communicate with call centers, ANEP unit can transfer its ID information and establish a two-way 

voice communication either :

 

 

• 

In a single calls,

                 

             • 

or two seperate call.

         

 The recommanded method (with respect to European specifications), is to make a single call 

          (the delay time is optimized.

3.4.2  - Programming table for a single call.

       

Telephone N°

Type of data

Type of communication

Call center

Memory # 101

Passenger and tech alarm

Data & audio

Main call center

Memory # 102

Passenger and tech alarm

Data & audio

Backup call center

Memory # 103

Passenger and tech alarm

Data & audio

Backup call center

Memory # 104

Remote end of alarm

Data

Main call center

Memory # 105

Periodic call

Data

Call center for periodics calls

Memory # 106

Alarm data

Data

ANEPanywhere or client call center

Содержание BOX-C

Страница 1: ...ANEP BOX C www anepstore com PIT EMERGENCY TELEPHONE SYSTEM FOR LIFT...

Страница 2: ...ttribution 3 4 1 Transfer method 3 4 2 Programming table for a single call 3 5 Enabling and adjustment of parameters 3 5 1 Conversation timeout 3 5 2 Listen to call identification 3 5 3 Cyclic test pe...

Страница 3: ...hang up voice mode CALL TO ANEP S VOICE SERVER SVA PAGE17 6 1 Enable call to SVA 6 2 Making the call to SVA 6 3 Tests made 6 3 1 Audio reception test 6 3 2 ANEP BOX C serial number verification 6 3 3...

Страница 4: ...m the pit flooding detector 1 dual fonction key passenger trapped acknowledge and test call to ANEP voice server 1 key for technician alarm Up to 6 telephone numbers may be stored Automatic calling of...

Страница 5: ...ANEP BOX C Version 1 09 22 2014 5 1 3 Connecting ANEP BOX C module phone line Dry contact flood sensor Powered flood sensor...

Страница 6: ...performance of telephone line equipement depends largely upon the characteristics of the telephone line Particular care must be taken when cabling the phone line to avoid damaging the standard line ch...

Страница 7: ...ode 1 2 3 This code may be modified by the technician 1 to 7 digits See page 14 3 1 Enter programming mode Enter followed by the access code to enter programming mode Example using the factory default...

Страница 8: ...the acces code to enter programming mode enter the following sequences 303 then 1 if module 1 lift 1 or 303 then 2 if module 2 lift 2 or 303 then 3 if module 3 lift 3 or 303 then 4 if module 4 lift 4...

Страница 9: ...mming mode Factory default 123 001 Erasing of configuration and telephone numbers 101 Telephone number 1st Call center phone number 102 Telephone number 2nd Call center phone number 103 Telephone numb...

Страница 10: ...number 102 Secondary emergency call number 103 Third emergency call number 3 3 1 Programmaming memories 101 102 103 In programming mode example for the principle call number Enter the sequence 1 0 1 E...

Страница 11: ...sfer its ID information and establish a two way voice communication either In a single calls or two seperate call The recommanded method with respect to European specifications is to make a single cal...

Страница 12: ...site record must first be established in the software ANEPCENTER refer to the manual ANEPCENTER During programmation mode exit BOX C performs a periodic call immediately NOTE During cyclic call the ce...

Страница 13: ...at the factory 3 5 6 Gain Setting in intercom machinery and firefighter modes Ability to independently adjust the Speaker and microphone gains used for Intercom machinery and firefighter module modes...

Страница 14: ...elephone button is pushed BOX C calls the number in memory 101 caretaker Then it calls the number in memory 102 call center If the number called by memory 101 caretaker or 102 call center is are busy...

Страница 15: ...NC The sensor option must be installed in the following way in the pit The floaters at lower extremity above water level The connection and programming must be done in conditions i e no water conditio...

Страница 16: ...e unit is still on line 5 2 Automatically Hang Up Voice mode The unit automatically Hang Up if an engaged signal is detected or if the call timeout is reached ANEP BOX C plays a melody 10 seconds befo...

Страница 17: ...Special case make a call to SVA from from behind a PABX Pressing the 0 key at the end of the sequence means that the prefixe 0 will be dialled before the SVA number Direct line 1 2 3 Factory code SVA...

Страница 18: ...annouced by the SVA 6 3 3 Installation telephone number check The telephone number of the caller is annonced by SVA 6 3 4 Audio test A vocal message can be recorded and play back immediately by the SV...

Страница 19: ...mber for periodic calls 106 Telephone number for internet server 2 Communication 200 Selection of communication protocol 201 Voice call timeout 1 to 99 minutes 202 Call acknowledge by operator functio...

Страница 20: ...ANEP BOX C Version 1 09 22 2014 20 NOTE...

Страница 21: ...ANEP BOX C Version 1 09 22 2014 21 NOTE...

Страница 22: ...ANEP BOX C Version 1 09 22 2014 22 NOTE...

Страница 23: ...orte quel moment sans pr avis GARANTIE Ce produit est garanti 1 an compter de la date de facturation du produit l exception des batteries et des piles qui sont garanties 6 mois Toutefois cette garanti...

Страница 24: ...4 bis rue de Paris 94470 Boissy Saint L ger FRANCE Tel 33 1 45 98 34 44 Fax 33 1 45 69 75 45 www anepstore com...

Отзывы: