ANEP BOX-C
Version #1
09/22/2014
12
3.5 - Enabling and adjustment of parameters
3.5.1 - Conversation Timeout
Conversation timeout from 1 to 99 minutes (factory default = 3 minutes)
En mode programmation :
Enter the sequence : # 2 0 1
Then enter the conversation timeout (from 1 to 99) followed by « # »
3.5.2 - Listen to call identification
In programming mode :
Enter the sequence # 105
Enter the phone number for receiving data by the central reception with a FT 2008 , FT
1001 or FT 4004 modem and software ANEPCENTER® or compatible frontal.
Press the key « # »
A «site record» must first be established in the software ANEPCENTER®
(refer to the manual ANEPCENTER®)
During programmation mode exit, BOX-C performs a periodic call immediately
NOTE: During cyclic call, the central (AnepCenter or compatible) receiving the call can
reprogram the clock of the C-BOX.
3.5.3 - Cyclic test / Periodicity
In programming mode :
Enter the sequence # 301
Dial the number of days for the periodicity of the cyclic call 1, 2 or 3.
Default: 3 days. example: 2 days = 301 # 2 #
3.5.4 - Listen data transfer
To enable the technician working on the lift to know that the C-BOX module is in communication with
a reception central, all data exchanges are audible (low level).
NOTE: access to the programming mode is not possible during a phone call.
Содержание BOX-C
Страница 1: ...ANEP BOX C www anepstore com PIT EMERGENCY TELEPHONE SYSTEM FOR LIFT...
Страница 20: ...ANEP BOX C Version 1 09 22 2014 20 NOTE...
Страница 21: ...ANEP BOX C Version 1 09 22 2014 21 NOTE...
Страница 22: ...ANEP BOX C Version 1 09 22 2014 22 NOTE...
Страница 24: ...4 bis rue de Paris 94470 Boissy Saint L ger FRANCE Tel 33 1 45 98 34 44 Fax 33 1 45 69 75 45 www anepstore com...