.5.7 -
Configuration of the dual call mode
The dual call mode allows a call to a caretaker post (voice only), before making a call to
the call center(data and voice). In addition, if the function « Acknowledgement of a
trapped passenger call « is enabled, the caretaker will have to acknowledge the call by
entering the sequence « #1 « on his phone keypad. Without this acknowledgment,
BOX-C
will call back to the call center up to 6 times.
Configuration of the dual call mode :
To configure the dual call mode, enter in programming mode and dial the sequence #206#
The « telephone « memories should be programmed as follows :
memory 101 : phone number of the caretaker
memory 102 : phone number of the call center
Sequence of an alarm call :
When the emergency elevator telephone button is pushed,
BOX-C
calls the number in
memory 101 (caretaker).
Then it calls the number in memory 102 (call center).
If the number called by memory 101 (caretaker) or 102 (call center) is (are) busy,
the corresponding numbers are called back up to 6 times.
Disabling
dual call mode :
To disable the dual call mode, enter in programming mode and dial the sequence #207#
3.6 - Selection of communication protocol
3.6.1 -
ANEP Protocol
Default protocol, or set by the following key sequence :
After entering the access code programming, press
# 200
then 0, then
#
.
3.6.2 -
P100 Protocol
P100 protocol is set by the following key sequence :
After entering the access programming, press
# 200
then 1, then
#
.
3.7 - Adjusting the level of emissions of DTMF codes
Ability to adjust the transmission power DTMF codes to avoid echo phenomena when the
BOX-C
is connected to a GSM gateway.
By default power is set to -8 dBm.
After entering the access code programming
Press
# 409
then a value of N 0-12 then
#
Powser (dBm).
Содержание BOX-C
Страница 1: ...ANEP BOX C www anepstore com PIT EMERGENCY TELEPHONE SYSTEM FOR LIFT...
Страница 20: ...ANEP BOX C Version 1 09 22 2014 20 NOTE...
Страница 21: ...ANEP BOX C Version 1 09 22 2014 21 NOTE...
Страница 22: ...ANEP BOX C Version 1 09 22 2014 22 NOTE...
Страница 24: ...4 bis rue de Paris 94470 Boissy Saint L ger FRANCE Tel 33 1 45 98 34 44 Fax 33 1 45 69 75 45 www anepstore com...