PROPANE:
37mbar (14.86 in wg)
When using propane cylinders, connect a minimum
number of 47kg cylinders, as listed below, together with a
manifold before connecting to the union.
Use a minimum pipe size of ¾in bore.
Two 47kg Cylinders
LEC230/600, LEC230/700
and LEC380/740
Three 47kg Cylinders
LEC230/960 and
LEC380/980
Four 47kg Cylinders
LEC 380/1220 and
LEC380/1400
LEC 380/1900
WARNING! PROPANE CYLINDERS MUST BE USED
AND STORED IN ACCORDANCE WITH ‘THE HIGHLY
FLAMMABLE LIQUIDS AND LIQUIFIED
PETROLEUM GASES REGULATIONS 1972’, AND
SHOULD COMPLY WITH LPGA CODE OF PRACTICE
7, ‘STORAGE OF FULL AND EMPTY LPG
CYLINDERS AND CARTRIDGES’.
ELECTRICAL SUPPLY
External wiring to the water heater(s) must be installed in
accordance with current I.E.E. Regulations for the wiring
of buildings and to any Local Regulations that may apply.
The ECOflo range is designed to operate from a 230V,
single phase supply. The fuse rating is 5 amps.
The method of connection to the mains electrical supply
should facilitate complete electrical isolation of the
appliance, preferably by use of a fused double pole
switch or fused spur box serving only the heater. The
disconnection of the supply shall have a contact
separation of 3mm on all poles. The double pole switch
for the water heater electrical supply must be located
where it can be easily reached under all circumstances.
The point of connection to the mains electrical supply
should be readily accessible through a cable entry gland
at the rear of the appliance on the combustion assembly
surround.
Connect the electrical supply to the main control panel
terminal block via the cable gland. Mains input cable
should be 0.75mm² 3 core and should be connected to
the mains supply as detailed above.
Mains Voltage:
230V – IP 20
Frequency:
50Hz
Fuse:
5 Amps