34
COMMISSIONING
SECTION 4
Lighting the burner
1. Ensure gas supply is on.
2. Set thermostat control knob to the required water temperature. (See below).
3. Ensure time switch if fitted is in the ON position.
4. Move electrical ON/OFF switch to ON and the burner will light.
5. Check pilot and main gas connections at gas control valve using leak detection fluid
whilst burner is alight. Turn OFF, seal any leakages then re-test.
Shutting OFF burner
To shut OFF the burner move switch to OFF then turn OFF the gas service cock.
The water heater should only be turned OFF for long periods, eg holidays, or in an
emergency. Otherwise the heater should be left to operate under normal thermostat
control.
NB. When using a time control ensure the heater is not turned OFF before the final
water draw off occurs. This will ensure the water in the tank is left in a hot condition.
STANDARD
RANGE
AUTO IGNITION
MODELS
Fig 23.
Thermostat Control
Knob
On/Off Switch
Gas Control valve
THERMOSTAT SETTING
APPROX WATER TEMP.
1
2
3
104ºF
40ºC
131ºF
55ºC
158ºF
70ºC
Содержание 24/39
Страница 11: ...11 INSTALLATION SECTION 3 Standard Range Hi FloRange Fig3a Fig3b ...
Страница 19: ...19 INSTALLATION SECTION 3 Fig 6A Fig 7 ...
Страница 23: ...23 INSTALLATION SECTION 3 WATER CONNECTIONS Fig 9 Fig 10 ...
Страница 26: ...26 INSTALLATION SECTION 3 WATER CONNECTIONS Fig 13 Fig 14 ...
Страница 29: ...29 INSTALLATION SECTION 3 WATER CONNECTIONS Fig 17 Fig 18 ...
Страница 50: ...46 Hi Flo Model 32 143 Hi Flo Models 65 173 and 81 264 50 PARTS LIST AND ILLUSTRATIONS SECTION 9 ...
Страница 52: ...52 PARTS LIST AND ILLUSTRATIONS SECTION 9 Hi Flo Models 62 341 and 54 418 440 ...
Страница 56: ...56 PARTS LIST AND ILLUSTRATIONS SECTION 9 24 Volt Auto System Kit B258 24 Volt Auto System Kit B217 ...
Страница 93: ...93 Notes ...
Страница 94: ...94 Notes ...
Страница 95: ...95 Notes ...