APPENDICES
88
SERVICE PROCEDURE
D24-IV
Control Board Replacement
Control board replacement
Step 1: Disconnect Power
Depress
plastic
tabs
Slots in
control panel
Unhook tabs
from control
panel slots
To remove lower sensor
Remove clip, pull sensor out.
Step 2: Unplug wire connections from board.
Pull out sensor
Remove clip
Wire connections
DANGER
120 volt exposure. To avoid personal injury,
unplug while performing this procedure.
Page 34
23
25
24
26
Step 3: To remove board, tilt control panel to the right
and slide control hook tabs from slots in control panel.
IMPORTANT
When replacing lower sensor, make sure
sensor is fully inserted into the well and
securely held by the clip on the well groove.
(see photo 25)
Содержание 24/39
Страница 11: ...11 INSTALLATION SECTION 3 Standard Range Hi FloRange Fig3a Fig3b ...
Страница 19: ...19 INSTALLATION SECTION 3 Fig 6A Fig 7 ...
Страница 23: ...23 INSTALLATION SECTION 3 WATER CONNECTIONS Fig 9 Fig 10 ...
Страница 26: ...26 INSTALLATION SECTION 3 WATER CONNECTIONS Fig 13 Fig 14 ...
Страница 29: ...29 INSTALLATION SECTION 3 WATER CONNECTIONS Fig 17 Fig 18 ...
Страница 50: ...46 Hi Flo Model 32 143 Hi Flo Models 65 173 and 81 264 50 PARTS LIST AND ILLUSTRATIONS SECTION 9 ...
Страница 52: ...52 PARTS LIST AND ILLUSTRATIONS SECTION 9 Hi Flo Models 62 341 and 54 418 440 ...
Страница 56: ...56 PARTS LIST AND ILLUSTRATIONS SECTION 9 24 Volt Auto System Kit B258 24 Volt Auto System Kit B217 ...
Страница 93: ...93 Notes ...
Страница 94: ...94 Notes ...
Страница 95: ...95 Notes ...