![Andreoli Engineering ATOM 1000 Скачать руководство пользователя страница 130](http://html1.mh-extra.com/html/andreoli-engineering/atom-1000/atom-1000_operators-manual_2942479130.webp)
ANDREOLI
ENGINEERING
Operator’s Manual
Self-propelled sprayer ATOM
130/166
It is also possible to force a manual regeneration, following this procedure:
Engine coolant temperature must be > 65°C.
Set the engine at minimum revs.
Stop the machine in a safe place: no dry materials or flammable materials close to the machine.
Engage park brake.
Push the button
on the side dashboard, for 3 seconds. Engine revs will mount to 2000 rpm.
Regeneration takes about 20-30 minutes; at the end, the engine will reduce revs back to minimum.
Operator MUST keep under control regeneration operations.
At the end of the procedure, the machine can be used as normal.
If you keep pressed the regeneration button for more than 2 minutes, or if a short-circuit happens, the
engine ECU activates an error code, stops the regeneration procedure and disables the regeneration
button.
To restore the DPF manual regeneration functionality, ask to authorized service.
7.9.2
ATS
–
R754TE4
ATS system is based on a filter DOC (Oxicat catalyst) + POC:
1)
Exhausts temperature sensor
Filter outside can reach high temperature (> 600°C).
Danger! It may cause burns.
Service operations MUST be done by authorized staff. Wear adequate
protective devices.
7.9.3
Engine ECU
Engine ECU is located at the back of the machine, under the top cover.
1)
Engine ECU
1
1