Adjusting the Danfoss variable
displacement pump pressure and the
main valve relief pressure on an ECO80 #
004
40
Adjust the pressure sensing pressure on the pump to 350 psi (25 bar)
1. Loosen screw #1
2. Check pressure on LS gauge
If the pressure is lower than 350 psi (25 bar) tighten screw #2
If the pressure is higher than 350 psi (25 bar) loosen screw #2
Repeat step b and c, until you have 350 psi (25 bar) on the LS gauge