background image

 10 

2885 Country Drive  #190 · St. Paul, MN 55117 · 800-348-1316 · www.leaktools.com 

Set-up of The LeakTrac 2400 

 

 

1.  Look for a place to set up your LeakTrac 2400 that has a convenient connec-

tion to ground within 20 feet. Open the case and remove all components ex-

cept the Power Booster. 

  

2.  Plug the red banana plug from the Ground cable into the red socket of the 

Power Booster and attach the clamp to ground. 

 

 

 

 

Good connections to ground include: 

 

        Ladder anchors sockets 

                     Diving board anchor bolts 

                     Metal junction box conduit 

                     Any metal rod stuck into the ground 

 

 

 

If the ground you choose is painted, you 

must scrape through the paint to assure an electrical connection is made with the 

ground clamp. 

 

 

3.  Plug the black banana plug from the Input Float into the black socket on the 

Power Booster. Unwind enough anchor cord to allow the float anchor to touch 

the bottom of the pool and toss the anchor and float into the pool so that the 

brass side of the float is down. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание LeakTrac Wireless 2400

Страница 1: ...INSTRUCTION MANUAL 2885 Country Dr 190 St Paul MN 55117 800 348 1316 www leaktools com Your Partner in Swimming Pool Leak Detection 2400...

Страница 2: ...no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be deter mined by turning the eq...

Страница 3: ...ck The sophisticated LeakTrac 2400 detects these Leak Tracks by measuring the differential voltage potential at different points in the pool and translates this in formation into audible clicking soun...

Страница 4: ...s neck Touch pad buttons and LED indicators offer the following user interface SENSITIVITY Use the up arrow button to toggle through three different input am plification settings Current setting will...

Страница 5: ...1 Red accepts the banana plug connector from the red Ground Cable 2 Black accepts the banana plug connector from the Input Float Cable A toggle switch turns the Booster on I and off 0 A LED indicator...

Страница 6: ...o make a connection to ground A length of insulated wire to red banana plug is used to connect to the red input jack on the Power Booster Headphones These standard headphones plug into the back of the...

Страница 7: ...to the pool the strongest Leak Track will be produced when there is only one path for the charge to connect to ground 3 Relative conductivity of different points of low resistance One weak Leak Track...

Страница 8: ...c 2400 Preliminary Steps Before using the LeakTrac 2400 first confirm that there is indeed a leak in the pool by using the Leakalyzer or doing a bucket test Next pressure test the plumbing lines and r...

Страница 9: ...over can be removed by placing the hose without the pump into the water below the bottom edge of the cover Warning This light cover is not intended for any use where the rubber inner tube gasket conta...

Страница 10: ...tach the clamp to ground Good connections to ground include Ladder anchors sockets Diving board anchor bolts Metal junction box conduit Any metal rod stuck into the ground If the ground you choose is...

Страница 11: ...electrical leakage is occurring If no variation in click rate occurs move the probe a few feet and repeat Note The Booster will turn off automatically one minute after the SPU has been turned off The...

Страница 12: ...ons Generally the signal will be most sharp at the highest possible power and click rate setting that gives rapid clicking when pointed toward the leak but no signal when pointed away User preferences...

Страница 13: ...is not necessarily leaking To find leaks in these situations move the probe close to the non leak connection to ground then turn the striped end of the probe away and survey the vinyl moving away from...

Страница 14: ...ly inserted into the jack on the back of the SPU Assure that batteries are good in Booster Check probe wire for wear on insulation Call Anderson Manufacturing Possible Cause Booster not working proper...

Страница 15: ...too much signal due to other ground connection Solution Turn Power down and re adjust Click Rate Cover lights remove ladders etc Assure liner above water line is not wet creating connection to coping...

Страница 16: ...y clean the plate with steel wool to keep it conductive Care As with any electrical equipment moisture will cause corrosion problems Do what you can to keep the equipment and the inside of the case dr...

Отзывы: