Installation

MOUNTING

Mount the unit in a DRY location. Allow at least 4 inches of clearance around the heat sink 

fins for adequate cooling. 

POWER CONNECTION

The unit is supplied with power leads about 3 feet long. This should normally be adequate to 

connect to a source of power. If you must extend the power leads, be sure to use at least a 

good quality (typeTEW) AWG8 wire. The wire colours are:  

All connections should be made inside an appropriate junction box. Refer to the specifications 

table for the correct sizing of the circuit breaker in the distribution panel.

Red - Positive

Black- Negative

Designed and manufactured by: 

ANALYTIC SYSTEMS WARE (1993) LTD.

8128 River Way 
Delta, BC  V4G 1K5  Canada

p. 604.946.9981  f. 604.946.9983 
tf. 800.668.3884 US/Canada

www.analyticsystems.com

[email protected]  Revised August 2014

General

Efficiency

> 80 % @ maximum output

Stages

2 or 3

Temp. Range

-25 to +40o C @ maximum output

Isolation

Input-Output & Input-Case 1500 Vdc
Output-Case 500 VDC (1500Vdc @ 48 V Out)

Length

14.5 in / 36.8 cm

Width

9.9 in / 25.1 cm

Height

5.5 in / 14.0 cm

Clearance

1 Inch (2.5 cm) all around

Material

Marine Grade Aluminum

Finish

Black Anodize / Black Powder Epoxy

Fastenings

18-8 Stainless

Weight

12 lb / 5.5 kg

Содержание BCD1000 Series

Страница 1: ...IES Battery Charger 8128 River Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 800 668 3884 US CANADA www analyticsystems com An ISO9001 and AS9100 Registered Company Battery Chargers In...

Страница 2: ...Copyright 2005 2014 Analytic Systems Ware 1993 Ltd...

Страница 3: ...wer switch to off position ALL BATTERY CHARGERS 1 WARNING RISK OF EXPLOSIVE GASES i i WORKING IN VICINITY OF A LEAD ACID BATTERY IS DANGEROUS BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY O...

Страница 4: ...and recommended rates of charge xiii Add distilled water in each cell until battery acid reaches level specified by battery manufacturer This helps purge excessive gas from cells Do not overfill For...

Страница 5: ...be added factory option to allow monitoring of charg ing current and charging voltage Specifications Input Voltages Nominal ip 110 250 300 Actual Vdc 100 140 230 280 280 360 Input Amps max 14 8 6 5 5...

Страница 6: ...de an appropriate junction box Refer to the specifications table for the correct sizing of the circuit breaker in the distribution panel Red Positive Black Negative Designed and manufactured by ANALYT...

Страница 7: ...es will reach the float voltage at which time the charging light will go off and the charging current will reduce as necessary to maintain the batteries at that voltage You may check this OUTPUT CONNE...

Страница 8: ...al charge 100 75 50 25 0 Bulk Constant Current Float Constant Volts Time Two Stage Charge Volts Amps 100 75 50 25 0 Bulk Constant Current Absorption Constant Volts Float Constant Volts Time Three Stag...

Страница 9: ...icators to determine the cause of the shutdown CHARGING Indicates that the battery charger is charging the batteries If the LED is not on the batteries may be fully charged and the charger is supplyin...

Страница 10: ...ors then turn it off again Remove the eight screws holding on the cover Turn the unit upside down remove the cover and locate J22 It will be next to the relay as is shown in the above diagram Simply m...

Страница 11: ...remotely as well as duplicating all the diagnostic indicators and audible alarm REMOTE CONNECTOR This connector is located on the side of the unit Important To prevent the possibility of High Voltage...

Страница 12: ...er will charge the battery at approximately 10 of its normal rate i e 4 amps for a 40 amp charger until the battery reaches equalize voltage and then the current reduces as necessary to maintain the b...

Страница 13: ...the battery The sensor may be placed on top of the battery but it should be secured to the battery so as to prevent it from losing contact with the battery Battery Charger Temperature Compensation The...

Страница 14: ...p Components Conformal Dipping and RTV Compound Option w Wide Temperature Operation 40 to 55 C incl Option SM High Voltage Protection on the DC Input Side Option d Paralleling Diodes Option FI Forklif...

Страница 15: ...ng will incur additional charges and are the responsibility of the Purchaser 6 Analytic Systems reserves the right to void the warranty if a Labels identification marks or serial numbers are removed o...

Страница 16: ...Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 800 668 3884 US CANADA www analyticsystems com An ISO9001 and AS9100 Registered Company Battery Chargers Inverters Power Supplies Voltage...

Отзывы: