background image

15

Limited Warranty

1.  The equipment manufactured by Analytic Systems Ware (1993) Ltd. (the “Warrantor”) is warranted to be free 

from defects in workmanship and materials under normal use and service.

2.  This warranty is in effect for:

a.  3 Years from date of purchase by the end user for standard products offered in our catalog.
b.  2 Years from date of manufacture for non-standard or OEM products
c.  1 Year from date of manufacture for encapsulated products.

3.  Analytic Systems will determine eligibility for warranty from the date of purchase shown on the warranty card 

when returned within 30 days, or

a.  The date of shipment by Analytic Systems, or
b.  The date of manufacture coded in the serial number, or 
c.  From a copy of the original purchase receipt showing the date of purchase by the user.

4.  In case any part of the equipment proves to be defective, the Purchaser should do the following:

a.  Prepare a written statement of the nature of the defect to the best of the Purchasers knowledge, and 

include the date of purchase, the place of purchase, and the Purchasers name, address and telephone 

number.

b.  Call Analytic Systems at 800-668-3884 or 604-946-9981 and request a return material authorization 

number (RMA).

c.  Return the defective part or unit along with the statement at the Purchasers expense to the Warrantor; 

Analytic Systems Ware (1993) Ltd., 8128 River Way, Delta, B.C., V4G 1K5, Canada.

5.  If upon the Warrantor’s examination the defect proves to be the result of defective material or workmanship, 

the equipment will be repaired or replaced at the Warrantor’s option without charge, and returned to the 

Purchaser at the Warrantor’s expense by the most economical means. Requests for a different method of return 

or special handling will incur additional charges and are the responsibility of the Purchaser.

6.  Analytic Systems reserves the right to void the warranty if:

a.  Labels, identification marks or serial numbers are removed or altered in any way.
b.  Our invoice is unpaid.
c.  The defect is the result of misuse, neglect, improper installation, environmental conditions,  non-autho-

rized repair, alteration or accident.

7.  No refund of the purchase price will be granted to the Purchaser, unless the Warrantor is unable to remedy the 

defect after having a reasonable number of opportunities to do so.

8.  Only the Warrantor shall perform warranty service. Any attempt to remedy the defect by anyone else shall 

render this warranty void.

9.  There shall be no warranty for defects or damages caused by faulty installation or hook-up, abuse or misuse of 

the equipment including exposure to excessive heat, salt or fresh water spray, or water immersion except for 

equipment specifically stated to be waterproof.

10. No other express warranty is hereby given and there are no warranties that extend beyond those described 

herein. This warranty is expressly in lieu of any other expressed or implied warranties, including any implied 

warranty of merchantability, fitness for the ordinary purposes for which such goods are used, or fitness for a 

particular purpose, or any other obligations on the part of the Warrantor or its employees and representatives.

11. There shall be no responsibility or liability whatsoever on the part of the Warrantor or its employees and rep-

resentatives for injury to any person or persons, or damage to property, or loss of income or profit, or any other 

consequential or resulting damage which may be claimed to have been incurred through the use or sale of the 

equipment, including any possible failure of malfunction of the equipment, or part thereof.

12. The Warrantor assumes no liability for incidental or consequential damages of any kind

Содержание BCD1000 Series

Страница 1: ...IES Battery Charger 8128 River Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 800 668 3884 US CANADA www analyticsystems com An ISO9001 and AS9100 Registered Company Battery Chargers In...

Страница 2: ...Copyright 2005 2014 Analytic Systems Ware 1993 Ltd...

Страница 3: ...wer switch to off position ALL BATTERY CHARGERS 1 WARNING RISK OF EXPLOSIVE GASES i i WORKING IN VICINITY OF A LEAD ACID BATTERY IS DANGEROUS BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY O...

Страница 4: ...and recommended rates of charge xiii Add distilled water in each cell until battery acid reaches level specified by battery manufacturer This helps purge excessive gas from cells Do not overfill For...

Страница 5: ...be added factory option to allow monitoring of charg ing current and charging voltage Specifications Input Voltages Nominal ip 110 250 300 Actual Vdc 100 140 230 280 280 360 Input Amps max 14 8 6 5 5...

Страница 6: ...de an appropriate junction box Refer to the specifications table for the correct sizing of the circuit breaker in the distribution panel Red Positive Black Negative Designed and manufactured by ANALYT...

Страница 7: ...es will reach the float voltage at which time the charging light will go off and the charging current will reduce as necessary to maintain the batteries at that voltage You may check this OUTPUT CONNE...

Страница 8: ...al charge 100 75 50 25 0 Bulk Constant Current Float Constant Volts Time Two Stage Charge Volts Amps 100 75 50 25 0 Bulk Constant Current Absorption Constant Volts Float Constant Volts Time Three Stag...

Страница 9: ...icators to determine the cause of the shutdown CHARGING Indicates that the battery charger is charging the batteries If the LED is not on the batteries may be fully charged and the charger is supplyin...

Страница 10: ...ors then turn it off again Remove the eight screws holding on the cover Turn the unit upside down remove the cover and locate J22 It will be next to the relay as is shown in the above diagram Simply m...

Страница 11: ...remotely as well as duplicating all the diagnostic indicators and audible alarm REMOTE CONNECTOR This connector is located on the side of the unit Important To prevent the possibility of High Voltage...

Страница 12: ...er will charge the battery at approximately 10 of its normal rate i e 4 amps for a 40 amp charger until the battery reaches equalize voltage and then the current reduces as necessary to maintain the b...

Страница 13: ...the battery The sensor may be placed on top of the battery but it should be secured to the battery so as to prevent it from losing contact with the battery Battery Charger Temperature Compensation The...

Страница 14: ...p Components Conformal Dipping and RTV Compound Option w Wide Temperature Operation 40 to 55 C incl Option SM High Voltage Protection on the DC Input Side Option d Paralleling Diodes Option FI Forklif...

Страница 15: ...ng will incur additional charges and are the responsibility of the Purchaser 6 Analytic Systems reserves the right to void the warranty if a Labels identification marks or serial numbers are removed o...

Страница 16: ...Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 800 668 3884 US CANADA www analyticsystems com An ISO9001 and AS9100 Registered Company Battery Chargers Inverters Power Supplies Voltage...

Отзывы: