19
VIO 4K TPP PROGRAMMER'S GUIDE FOR v02.00.7X
3.5
Loading a Preset from memory
3.5.1
Usage
A simple way to control a VIO 4K™ product is to record the
entire device’s screens content in its memories, using the Web
RCS, during the initial setup. These memories can then be
remotely recalled by a controller.
The “recall Preset from memory” action can be used
automatically and with the manual apply mode.
This command allows to load a previously memorized preset.
3.5.2
Detailed commands sequence
Load a preset from memory:
Syntax : <bank>,
1PKrcr
L
F
<bank> is the memory index (16 memories addressed from 0 to 15).
3.5.3
Example of preset recall (auto-apply mode)
Picture 10: Example of load preset from memory
In auto-apply mode, the commutation with transition is directly called.
Picture 9: Select a preset - Web RCS