10.6.2
Set trigger timecoded with System Wallclock
The Wallclock timecode provider emits the server time and date. It can be used to run cues at set times or
even more complex scheduling patterns.
- Select a cue stack playback and select Wallclock as timecode provider.
- Set the trigger type to Timecode for the required cues and define the trigger times to Timecode column.
Set the input and output offsets for wallclock timecode if required.
Note
: The server wallclock may differ from the time on the computer which runs Commander.
- Set the server wallclock time with web configurator (see
- The Wallclock timecode is based on 24-hour clock (HH:MM:SS), cue trigger values between 00:00:00:000 and 23:59:59:999
Note: Wallclock timecode also contains date data. This may cause unexpected behavior with cue triggering if the current date differs from
the scheduled date (see more 9.7.)
Tip
: The current Wallclock time will be displayed at the bottom of the Playback window.
- If cues need to be scheduled to repeat more than once a day, see more information on cue scheduling for repeating
events daily, weekly or on certain dates from chapter 9.7.
Fig. 105 -