![Analog Devices ADM1026 Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/analog-devices/adm1026/adm1026_preliminary-technical-data_2939817030.webp)
ADM1026
PRELIMINARY TECHNICAL DATA
– 3 0 –
REV. PrL
PRELIMINAR
Y
TECHNICAL
DA
TA
ADM1026 REGISTERS
TABLE 5. ADDRESS POINTER REGISTER
Bit
Name
R/W
Description
7-0
Address Pointer
Write
Address of ADM1026 Registers. See the tables below for detail.
TABLE 6. LIST OF REGISTERS
Hex
Name
Power on Value
Description
Address
(Hex or Binary Bit 7 - 0)
00
Configuration 1
00h
Configures various operating parameters
01
Configuration 2
00h
Configures pins 1 to 9 for fan input or GPIO
02
Fan 0-3 Divisor
55h
Sets oscillator frequency for Fan 0 - 3 speed
measurement
03
Fan 4-7 Divisor
55h
Sets oscillator frequency for Fan 4 - 7 speed
measurement
04
Fan Speed 1
F F h
Contains value for fan speed DAC (analog fan
speed control) or minimum value for automatic fan
speed control
05
Fan Speed 2
F F h
Contains value for PWM fan speed control or
minimum value for automatic fan speed control
06
EEPROM Register 1
00h
For factory use only.
07
Configuration Register 3
00h
Config. register for
THERM,
VREF and GPIO16
08
GPIO Config 1
00h
Configures GPIO0 to GPIO3 as input or output
and as active high or active low
09
GPIO Config 2
00h
Configures GPIO4 to GPIO7 as input or output
and as active high or active low
0A
GPIO Config 3
00h
Configures GPIO8 to GPIO11 as input or output
and as active high or active low
0 B
GPIO Config 4
00h
Configures GPIO12 to GPIO15 as input or output
and as active high or active low
0 C
EEPROM Register 2
00h
For factory use only
0 D
Int Temp
THERM
Limit
37h (55
o
C)
High limit for
THERM
interrupt output based on
internal temperature measurement
0 E
TDM1
THERM
Limit
50h (80
o
C)
High limit for
THERM
interrupt output based on
remote channel 1 (D1) temperature measurement
0 F
TDM2
THERM
Limit
50h (80
o
C)
High limit for
THERM
interrupt output based on
remote channel 2 (D2) temperature measurement
10
Int Temp TMIN
28h (40
o
C)
TMIN value for automatic fan speed control based
on internal temperature measurement
11
TDM1 TMIN
40h (64
o
C)
TMIN value for automatic fan speed control based
on remote channel 1 (D1) temperature measurement
12
TDM2 TMIN
40h (64
o
C)
TMIN value for automatic fan speed control based
on remote channel 2 (D2) temperature measurement
13
EEPROM Register 3
00h
Configures EEPROM for read/write/erase etc.
14
Spare
00h
Not Used