5
November 2006
Single Input Operation with Ramping Down (JP5 Position 1-2)
A)
Base/Max is active; Starts at base speed and immediately ramps up to max speed.
B)
Base/Max is active; Max speed is reached (keeps running at max speed).
C)
Base/Max is inactive; Motor ramps down.
D)
Pulses automatically stop when base speed is reached.
Note:
With single-input operation, jumper JP5 is used to select ramping down (Position 1-2), or
no ramping down (Position 2-3).
A
B
C
D
Max Speed
Base Speed
Off
Time
Speed
Connector P1:
Pin #
Description
1
Power Supply Ground (0VDC)
2
Power Supply Input (12VDC
-35VDC)
3
Stop/Run
4
Base/Max
5
Max Speed A/Max Speed B
6
Pulse Generator Clock Out
7
On/Off
8
Direction
9
External Clock
Connector P2:
Pin #
Description
1
External Potentiometer
2
External Potentiometer Wiper
3
External Potentiometer
Connector P3: (Two Motors)
Pin #
Description
1
Motor 1, Phase 1
2
Motor 1, Phase 3
3
Motor 1, Phase 2
4
Motor 1, Phase 4
5
Motor 1 Ground
6
Motor 2, Phase 1
7
Motor 2, Phase 3
8
Motor 2, Phase 2
9
Motor 2, Phase 4
10
Motor 2 Ground
Connector P3: (One Motor)
Pin #
Description
1
Motor 1, Phase 1
2
No Connect
3
No Connect
4
Motor 1, Phase 4
5
Motor Ground
6
No Connect
Connector Descriptions
July 2018
July 2018