background image

12

November 2006

A N A H E I M   A U T O M A T I O N

COPYRIGHT

 

Copyright 2002 by Anaheim Automation. All rights reserved. No part of this publication may be reproduced, 

transmitted, transcribed, stored in a retrieval system, or translated into any language, in any form or by 

any means, electronic, mechanical, magnetic, optical, chemical, manual,  or otherwise, without the prior 

written permission of Anaheim Automation, 4985 E Landon Drive, Anaheim, CA 92807. 

DISCLAIMER

Though every effort has been made to supply complete and accurate information in this manual, the 

contents are subject to change without notice or obligation to inform the buyer. 

In no event will Anaheim 

Automation be liable for direct, indirect, special, incidental, or consequential damages arising out 

of the use or inability to use the product or documentation.

  

Anaheim Automation’s general policy does not recommend the use of its’ products in life support appli-

cations wherein a failure or malfunction of the product may directly threaten life or injury. Per Anaheim 

Automation’s Terms and Conditions, the user of Anaheim Automation products in life support applications 

assumes all risks of such use and indemnifies Anaheim Automation against all damages.

LIMITED WARRANTY

All Anaheim Automation products are warranted against defects in workmanship, materials and construc-

tion, when used under Normal Operating Conditions and when used in accordance with specifications.  

This warranty shall be in effect for a period of twelve months from the date of purchase or eighteen months 

from the date of manufacture, whichever comes first. 

Warranty provisions may be voided if products 

are subjected to physical modifications, damage, abuse, or misuse.

Anaheim Automation will repair or replace at its’ option, any product which has been found to be defective 

and is within the warranty period, provided that the item is shipped freight prepaid, with previous authori-

zation (RMA#) to Anaheim Automation’s plant in Anaheim, California. 

TECHNICAL SUPPORT

If you should require technical support or if you have problems using any of the equipment covered by this 

manual, please read the manual completely to see if it will answer the questions you have. If you need 

assistance beyond what this manual can provide, contact your Local Distributor where you purchased the 

unit, or contact the factory direct.

Torque Speed Curves

July 2018

July 2018

Содержание MBC25PG1

Страница 1: ...Microstep Driver with Pulse Generator L010061 4985 E Landon Dr Anaheim CA 92807 e mail info anaheimautomation com 714 992 6990 fax 714 992 0471 website www anaheimautomation com A N A H E I M A U T O...

Страница 2: ...rt circuit over temperature and crossover current protection Ramping There are separate adjustments for acceleration and deceleration The ramp times are adjustable from 50 milliseconds to 1 0 seconds...

Страница 3: ...s not active the motor will be moving in the clockwise or direction When this input is active the motor will move in the counterclockwise or direction When two motors are used the second motor will mo...

Страница 4: ...base speed B Base Max is active Ramps up to max speed C Both inputs are still active Max speed is reached keeps running at max speed D Base Max is inactive and Stop Run is still active Ramps down to...

Страница 5: ...1 Pin Description 1 Power Supply Ground 0VDC 2 Power Supply Input 12VDC 35VDC 3 Stop Run 4 Base Max 5 Max Speed A Max Speed B 6 Pulse Generator Clock Out 7 On Off 8 Direction 9 External Clock Connecto...

Страница 6: ...Ordering Information POWER REQUIREMENTS 12 35VDC BASE MAX INPUT P1 PIN 4 BASESPEED INACTIVE MAX SPEED ACTIVE STOP RUN INPUT P1 PIN 3 STOP INACTIVE RUN ACTIVE DIRECTION INPUT P1 PIN 8 CW INACTIVE CWW...

Страница 7: ...Clocks N A JP4 External Max Speed Control On Board Max Speed Control N A JP5 Single Input Operation with Ramping Down Single Input Operation with No Ramping Down N A JP6 Speed Range 2 Speed Range 3 S...

Страница 8: ...8 November 2006 Hookup Diagrams One Motor Two Motors July 2018 July 2018...

Страница 9: ...uced Current Enabled Potentiometer Settings Peak Current Potentiometer Setting 0 5A 0 0 7A 10 0 9A 20 1 1A 30 1 3A 40 1 5A 50 1 7A 60 1 9A 70 2 1A 80 2 3A 90 2 5A 100 Microstep Modes Switch Settings M...

Страница 10: ...the motor when microstepping is determined differently from that of a full half step unipolar driver In the MBC25PG1 L a sine cosine output function is used in rotating the motor The output current fo...

Страница 11: ...eter Connecting the Step Motor The MBC25PG1 L is designed to accept either one or two motors For wiring of the motor refer to the pages containg the connector descriptions and hookup diagrams Note The...

Страница 12: ...roducts in life support applications assumes all risks of such use and indemnifies Anaheim Automation against all damages LIMITED WARRANTY All Anaheim Automation products are warranted against defects...

Отзывы: