6

November 2006

Part #

Description

MBC25PG1

Driver/Pulse Generator

MBC25PG1L

Driver/Pulse Generator with L Bracket for Vertical Mounting

DIN-209-188

Optional Din Rail Mountable Feet for MBC25PG1 

CON-6404289

Optional 9 pin, 0.156” IDC (AMP part no. 640428-9)

CON-16404280

Optional 10 pin, 0.156” IDC (AMP part no. 1-640428-0)

CON-6404403

Optional 3 pin, 0.100” IDC (AMP part no. 640440-3)

PSAM24V2.7A

Optional Power Supply 24V, 2.7A

Ordering Information

POWER REQUIREMENTS

12-35VDC

BASE/MAX INPUT (P1, PIN 4)

BASESPEED

INACTIVE

MAX SPEED

ACTIVE

STOP/RUN INPUT (P1, PIN 3)

STOP

INACTIVE

RUN

ACTIVE

DIRECTION INPUT (P1, PIN 8)

CW

INACTIVE

CWW

ACTIVE

ON/OFF INPUT (P1, PIN 7)

ON

INACTIVE

OFF

ACTVE

MAX A/MAX B INPUT (P1, PIN 3)

MAX SPEED A

INACTIVE

MAX SPEED B

ACTIVE

RAMP TIMES

LOWEST BASE SPEED TO HIGHEST MAX SPEED IN 50MS - 1.0 SEC

ACCELERATION/DECELERATION 

RATES

LOW SPEED RANGE

5000 - 10000 PULSE/SEC

2

HIGH SPEED RANGE

20000 - 400000 PULSES/SEC

2

OUTPUT CURRENT: TA = 25

o

C

MBC25PG1)

MIN

0.5A PEAK

MAX

2.0A PEAK (2.5A WITH AIR FLOW)

Specifications

July 2018

July 2018

Содержание MBC25PG1

Страница 1: ...Microstep Driver with Pulse Generator L010061 4985 E Landon Dr Anaheim CA 92807 e mail info anaheimautomation com 714 992 6990 fax 714 992 0471 website www anaheimautomation com A N A H E I M A U T O...

Страница 2: ...rt circuit over temperature and crossover current protection Ramping There are separate adjustments for acceleration and deceleration The ramp times are adjustable from 50 milliseconds to 1 0 seconds...

Страница 3: ...s not active the motor will be moving in the clockwise or direction When this input is active the motor will move in the counterclockwise or direction When two motors are used the second motor will mo...

Страница 4: ...base speed B Base Max is active Ramps up to max speed C Both inputs are still active Max speed is reached keeps running at max speed D Base Max is inactive and Stop Run is still active Ramps down to...

Страница 5: ...1 Pin Description 1 Power Supply Ground 0VDC 2 Power Supply Input 12VDC 35VDC 3 Stop Run 4 Base Max 5 Max Speed A Max Speed B 6 Pulse Generator Clock Out 7 On Off 8 Direction 9 External Clock Connecto...

Страница 6: ...Ordering Information POWER REQUIREMENTS 12 35VDC BASE MAX INPUT P1 PIN 4 BASESPEED INACTIVE MAX SPEED ACTIVE STOP RUN INPUT P1 PIN 3 STOP INACTIVE RUN ACTIVE DIRECTION INPUT P1 PIN 8 CW INACTIVE CWW...

Страница 7: ...Clocks N A JP4 External Max Speed Control On Board Max Speed Control N A JP5 Single Input Operation with Ramping Down Single Input Operation with No Ramping Down N A JP6 Speed Range 2 Speed Range 3 S...

Страница 8: ...8 November 2006 Hookup Diagrams One Motor Two Motors July 2018 July 2018...

Страница 9: ...uced Current Enabled Potentiometer Settings Peak Current Potentiometer Setting 0 5A 0 0 7A 10 0 9A 20 1 1A 30 1 3A 40 1 5A 50 1 7A 60 1 9A 70 2 1A 80 2 3A 90 2 5A 100 Microstep Modes Switch Settings M...

Страница 10: ...the motor when microstepping is determined differently from that of a full half step unipolar driver In the MBC25PG1 L a sine cosine output function is used in rotating the motor The output current fo...

Страница 11: ...eter Connecting the Step Motor The MBC25PG1 L is designed to accept either one or two motors For wiring of the motor refer to the pages containg the connector descriptions and hookup diagrams Note The...

Страница 12: ...roducts in life support applications assumes all risks of such use and indemnifies Anaheim Automation against all damages LIMITED WARRANTY All Anaheim Automation products are warranted against defects...

Отзывы: