UDM-ABB-8-SIG Audio Breakout Box
73
UDM-0808-SIG, UDM-RX02N and UDM-ABB-8-SIG Operation /Reference Guide
2.
Connect the other end of the Cascade Cable to the appropriate AUDIO IN port on the ABB (1-4 or 5-8):
Use the AUDIO IN port labeled 1-4 to connect to the CASCADE 1-4 (OUT) port on the UDM
Hub.
Use the AUDIO IN port labeled 5-8 to connect to the CASCADE 5-8 (OUT) port on the UDM
Hub.
3.
Connect a UDM Cascade cable to the remaining Cascade Out port on the UDM-0808-SIG (CASCADE
1-4 or CASCADE 5-8), and connect the other end of the UDM Cascade cable to the appropriate AUDIO
IN port on the UDM-ABB-8-SIG.
Connecting Audio Outputs
The UDM-ABB-8-SIG provides 8 sets of audio output ports (RCA and SPDIF).
Use standard audio cables to connect the ABB to up to eight audio playback devices.
UDM-ABB-8-SIG Configuration
There is no direct configuration of the ABB. Rather, audio cascade options are configured on the source Hub
itself (via the "SFI" Send Command described below).
"SFI" Send Command
Use the "SFI" Send Command (on the source UDM-0808-SIG Hub) to specify whether the cascaded audio
output on the source Hub will follow either:
the local input (a source device connected directly to the Hub)
- or -
the input that has been programmatically switched to the associated output port (see the
SEND_COMMANDs section on page 15).
For example, the cascade output for Input A on the source Hub can either be the signal from input A, or it
can be whatever signal is switched through to port 1 from the source Hub.
Syntax:
SEND_COMMAND <DEV>, "'SFI<I#>F<F#>'"
Audio clock data is taken from the AUDIO IN 1-4 port, hence a valid connection must
be made to this input for the ABB to work properly. The AUDIO IN 5-8 port is only
used if you intend to cascade audio from more than four outputs on the UDM Hub.
FIG. 64
UDM-ABB-8-SIG - Audio Output connectors
Digital Audio (SPDIF) Out
Analog Audio (L/R) Out
Refer to the UDM-0808-SIG NetLinx Programming
for a listing of
all Send Commands supported by the UDM-0808-SIG.
Содержание UDM-RX02N
Страница 22: ...UDM 0808 SIG Wiring and Connections 12 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...
Страница 44: ...UDM 0808 SIG WebConsole 34 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...
Страница 48: ...UDM 0808 SIG Firmware Upgrades 38 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...
Страница 68: ...UDM RX02N NetLinx Programming 58 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...
Страница 72: ...UDM RX02N Firmware Upgrades 62 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...
Страница 76: ...UDM RX02N IR File Transfers 66 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...
Страница 80: ...UDM RC05 Multi Format IR Remote Control 70 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...