UDM-0808-SIG NetLinx Programming
18
UDM-0808-SIG, UDM-RX02N and UDM-ABB-8-SIG Operation /Reference Guide
UDM-0808-SIG SEND COMMANDs (Cont.)
"'MMOFF'"
Configures the Hub
as a Target (Slave)
Hub in a cascaded
system.
This command configures the cascade video inputs and outputs to be correctly driven
and designates this Hub to receive audio and data clocks from a cascaded Source Hub.
This command takes effect the next time the Hub is rebooted (via the RESET command
or a power cycle).
Syntax:
SEND_COMMAND <DEV>,"'MMOFF'"
Example:
SEND_COMMAND dvUDM,"'MMOFF'"
Sets this Hub to Target Mode.
Note
: If Source or Target mode is changed, then the Hub must be rebooted via the
"'RESET'" Send Command. When changing a Hub from a Target Hub back to a Source
Hub, you must send the MMON command, RESET the unit, allow it to come online,
then RESET it again.
"'MMON'"
Configures the Hub
as the Source
(Master) Hub in a
cascaded system.
There can only be one Source Hub in a chain. This command configures the cascade
video outputs to be correctly driven and designates this Hub to generate audio and data
clocks. This command takes effect the next time the Hub is rebooted (via the RESET
command or a power cycle).
Syntax:
SEND_COMMAND <DEV>,"'MMON'"
Example:
SEND_COMMAND dvUDM,"'MMON'"
Sets this Hub to Master Mode.
Note
: If Source or Target mode is changed, then the Hub must be rebooted via the
"'RESET'" Send Command. When changing a Hub from a Target Hub back to a Source
Hub, you must send the MMON command, RESET the unit, allow it to come online,
then RESET it again.
"?MM"
Shows whether the
Hub is set to be a
cascade Master
(MMON) or a
cascade Target
(Slave) (MMOFF).
Syntax:
SEND_COMMAND <DEV>,"'?MM'"
Example:
SEND_COMMAND dvUDM,"'?MM'"
"'RESET'"
Performs a soft boot
on the Hub.
Syntax:
SEND_COMMAND <DEV>,"'RESET'"
Example:
SEND_COMMAND dvUDM,"'RESET'"
Reboots the Hub.
Note
: If Source or Target mode is changed, then the Hub must be rebooted via the
"'RESET'" Send Command. When changing a Hub from a Target Hub back to a Source
Hub, you must send the MMON command, RESET the unit, allow it to come online,
then RESET it again.
Содержание UDM-RX02N
Страница 22: ...UDM 0808 SIG Wiring and Connections 12 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...
Страница 44: ...UDM 0808 SIG WebConsole 34 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...
Страница 48: ...UDM 0808 SIG Firmware Upgrades 38 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...
Страница 68: ...UDM RX02N NetLinx Programming 58 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...
Страница 72: ...UDM RX02N Firmware Upgrades 62 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...
Страница 76: ...UDM RX02N IR File Transfers 66 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...
Страница 80: ...UDM RC05 Multi Format IR Remote Control 70 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...
Страница 86: ...UDM ABB 8 SIG Audio Breakout Box 76 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...