For example, if the UDM-0808-SIG is using it’s default device number assignment of 05600, and there are
eight UDM-RX02N receivers connected to all eight UDM Output ports on the Hub, then the device numbering
would be assigned as follows:
UDM-0808-SIG = device number 05600
UDM-RX02N connected to UDM Output Port #1 = device number 05601
UDM-RX02N connected to UDM Output Port #2 = device number 05602
UDM-RX02N connected to UDM Output Port #3 = device number 05603
UDM-RX02N connected to UDM Output Port #4 = device number 05604
UDM-RX02N connected to UDM Output Port #5 = device number 05605
UDM-RX02N connected to UDM Output Port #6 = device number 05606
UDM-RX02N connected to UDM Output Port #7 = device number 05607
UDM-RX02N connected to UDM Output Port #8 = device number 05608
Therefore, it important to avoid assigning device numbers that will conflict with this auto-numbering scheme.
Reserve the eight device numbers following the UDM Hub’s device number assignment for up to eight UDM-
RX02N receivers.
In the device tree, each UDM-RX02N Receiver shows three ports (FIG. 13)
These three ports relate directly to the three types of NetLinx commands recognized by the UDM-RX02N:
Port 1 - SEND_COMMANDS/LEVELS and Button Pushes
Port 2 - SERIAL (RS232) SEND_COMMANDS
Port 3 - IR SEND_COMMANDS
Refer to the UDM-RX02N NetLinx Programming section on page 49 for instructions on programming the
UDM-RX02N.
LEVELs
It is not required that the UDM-RX02N receivers are connected to the UDM Output
ports on the Hub in sequential order. For example, if you had three UDM-RX02N
units, plugged into UDM Outputs 2, 5 and 7, the device numbers (assuming the
default device number of the UDM-0808-SIG - 05600) would be 05602, 05605 and
05607.
FIG. 13
NetLinx Studio Online Tree - Ports 1-3 on each connected UDM-RX02N
Ports 1-3 on UDM-RX02N
(device number 06931)
Port 1 - main device port / IR Receiver
Port 2 - Serial (RS232) port
Port 3 - IR device port
When transferring files to RX02Ns, the UDM-0808-SIG Hub to which the RX02Ns are
connected must be rebooted in order for the files to be transferred from the Hub to
the Receivers.
Level Function
33
Internal temperature (in deg C)
Содержание UDM-RX02N
Страница 22: ...UDM 0808 SIG Wiring and Connections 12 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...
Страница 44: ...UDM 0808 SIG WebConsole 34 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...
Страница 48: ...UDM 0808 SIG Firmware Upgrades 38 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...
Страница 68: ...UDM RX02N NetLinx Programming 58 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...
Страница 72: ...UDM RX02N Firmware Upgrades 62 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...
Страница 76: ...UDM RX02N IR File Transfers 66 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...
Страница 80: ...UDM RC05 Multi Format IR Remote Control 70 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...
Страница 86: ...UDM ABB 8 SIG Audio Breakout Box 76 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...