Programming Ethernet Keypads

28

Instruction Manual - Novara Ethernet Keypads

Notes on Specific Telnet Clients

Telnet and terminal clients will have different behaviors in some situations. This section states some of the known 
anomalies.

Windows Client Programs

Anomalies occur when using a Windows™ client if you are not typing standard ASCII characters (i.e. using the keypad 
and the ALT key to enter decimal codes). Most programs will allow you to enter specific decimal codes by holding ALT 
and using keypad numbers. 

For example, hold ALT, hit the keypad 1, then hit keypad 0, then release ALT. The standard line feed code is entered 
(decimal 10). Windows will perform an ANSI to OEM conversion on some codes entered this way because of the way 
Windows handles languages and code pages. 

The following codes are known to be altered, but others may be affected depending on the computer's setup.

Characters 

15

21

22

, and

 any characters above 127

.

This affects both Windows Telnet and Terminal programs.

Linux Telnet Client

The Linux Telnet client has three anomalies that are known at this time:



A null (\00) character is sent after a carriage return.



If an ALT 255 is entered, two 255 characters are sent (per the Telnet RAFT).



If the code to go back to command mode is entered (ALT 29 which is ^]), the character is not sent, but Telnet 

command mode is entered.

Enabling/Disabling Telnet on the Keypad

By default, Telnet is enabled on all Metreau keypads. The default Telnet port is 

23

.

You can change the Telnet port by using the SET TELNET PORT command (see page 27). Setting the Telnet port to zero 
disables Telnet access.

The SET TELNET PORT command requires a reboot to enable new settings.

Note: 

The only way to re-enable Telnet once it has been disabled is to reset the unit to the factory default firmware 

image. See the Simulating the ID Pushbutton

section on page 9

 for details.

Terminal Commands (Cont.)

Command

Description

SHOW CONNECTION STATS

Show the connection statistics for the device. 

Output similar to the following example: 

>show connection stats 
Connection Statistics 
                  Total             Last 15 Minutes 
                  =====             =============== 
ICSP Messages:    10039 received    333 received 
                  10038 transmitted 333 transmitted 
Blink Messages:   5014 received     166 received 

IP Statistics: 
   RX packets:29298 errors:0 discarded:0 
   TX packets:15286 errors:0 discarded:0

SHOW LOG

Display the message log.

Syntax:

SHOW LOG <start>

• Use <start> to specify the message number to start displaying

• Use <all> to display all messages.

Содержание Novara SP-08-E-US

Страница 1: ...PDF provided by Conference Room AV AMX HPX U400 SP 08 E Novara 8 Button Keypad Module for HydraPort Table Boxes...

Страница 2: ...Instruction Manual Keypads Novara Ethernet Keypads SP 08 E US Latest Release 05 18 2015...

Страница 3: ...ked on the outside of each box The RMA is valid for a 30 day period After the 30 day period the RMA will be cancelled Any shipments received not consistent with the RMA or after the RMA is cancelled w...

Страница 4: ...t Keypads 9 Overview 9 Locating the IP Address of the Keypad 9 Simulating the ID Pushbutton 9 Toggling Between IP Addressing Modes DHCP and Static IP 10 Assigning a Device ID to a Keypad 10 Resetting...

Страница 5: ...21 REBOOT 21 SET_NDX_DESC 21 Telnet User Name and Password 22 Additional Notes 22 Setting a Telnet User Name and Password 22 Telnet Commands 23 or Help 23 DEVICE STATUS 23 EXIT 23 FACTORYFWIMAGE 23 GE...

Страница 6: ...uction Manual Novara Ethernet Keypads SHOW CONNECTION LOG 27 Notes on Specific Telnet Clients 28 Windows Client Programs 28 Linux Telnet Client 28 Enabling Disabling Telnet on the Keypad 28 SHOW CONNE...

Страница 7: ...iv Instruction Manual Novara Ethernet Keypads Table of Contents...

Страница 8: ...net Keypad FIG 1 interfaces over Ethernet and receive power via any Power over Ethernet PoE injector or switch which conforms to the 802 3af standard Novara Ethernet Keypads include FIG 1 Novara 8 But...

Страница 9: ...Connector 10 100 Button Layout 8 buttons blue backlit buttons with controllable feedback Rear Panel Connector Ethernet RJ 45 Ethernet Connector 10 100 Dimensions SP 08 E US 4 11 16 x 2 15 16 x 1 1 16...

Страница 10: ...inimum Internal Clearance for 1 Gang US Conduit Boxes To ensure a proper fit with sufficient clearance US style Novara Keypads require the following minimum internal dimensions within the conduit box...

Страница 11: ...16 button Keypads 8 Button Keypads can be configured for button numbers 1 8 9 16 17 24 or 25 32 16 Button Keypads can be configured for button numbers 1 16 or 17 32 FIG 3 Keypads Button Layout 1 2 3...

Страница 12: ...you to use either straight through or crossover Ethernet cables The port LEDs show communication activity connection status speeds and mode information The LAN port also receives its power via the LAN...

Страница 13: ...standard The network must be connected through the PoE injector to send power to the Keypad 1 Connect the PoE injector to an AC outlet 100 240V using a standard power cord 2 Connect the switch categor...

Страница 14: ...learance US style Novara Keypads require the following minimum internal dimensions within the conduit box US 1 Gang HWD 2 9 x 2 1 x 2 5 74 mm x 53 mm x 64 mm These minimum interior dimensions will mai...

Страница 15: ...Installation 8 Instruction Manual Novara Ethernet Keypads...

Страница 16: ...es 3 Right click the Novara Ethernet Keypad and select Network Bind Unbind Device from the menu that appears The Bind Unbind Device dialog opens 4 By default the selected keypad appears in the Device...

Страница 17: ...s buttons 1 and 2 on the keypad to assign a device address to the keypad See the NetLinx Studio Instruction Manual or consult the online help tool in NetLinx Studio for more information Resetting the...

Страница 18: ...your own button labels on acetate for custom button labeling Removing Replacing Button Labels The button labels on Novara Ethernet Keypads are acetate inserts that fit inside the key caps installed on...

Страница 19: ...on label to fit inside the Key Caps Custom button labels must be cut to a 0 472 12 mm square to fit securely inside the Key Caps The thickness of the acetate used must not exceed 004 0 10 mm 2 Place t...

Страница 20: ...ow these procedures closely the bottom of the Key Cap must be installed on the pushbutton before the Key Cap clips engage or there is a risk of the button being misaligned Also note that removing the...

Страница 21: ...Cap is installed 3 Gently replace the Key Cap on the pushbutton Verify that the vertical orientation of the Button Label is correct relative to the Novara keypad Align the Key Cap with the target pus...

Страница 22: ...for details 1 In NetLinx Studio click on the OnLine Tree tab in the Workspace Bar to view the devices on the System 2 Click Display and select Refresh System from the context menu This establishes a n...

Страница 23: ...ated devices including the Device Controller are listed in the OnLine Tree 4 In NetLinx Studio select Tools Firmware Transfers Send to NetLinx Device FIG 13 The Send to NetLinx Device dialog opens 5 l...

Страница 24: ...new information 3 Click Done to close the Device Addressing dialog 4 Click Reboot from the Tools Reboot the Master Controller dialog and wait for the System Master to reboot Note The STATUS and OUTPU...

Страница 25: ...Upgrading Firmware 18 Instruction Manual Novara Ethernet Keypads...

Страница 26: ...thernet Keypads including NetLinx and Telnet commands Button Layouts The following illustrations indicate the button numbers for the Novara Ethernet Keypads SP 08 E US Channels Channels on Novara Ethe...

Страница 27: ...llumination in the Off state 0 EXPANSION Allows NetLinx code to query the keypad to determine whether any expansion keypads are attached to it Syntax EXPANSION Example SEND_COMMAND DEVICE_1 EXPANSION...

Страница 28: ...0 44 Copyright AMX LLC If a Telnet password is set then user credentials are required Enter username Enter protected password Welcome to SP 08 E US v1 0 44 Copyright AMX LLC SEND_COMMANDs Cont Command...

Страница 29: ...ich will then present the password prompt Here the defined password must be entered in order to successfully open the Telnet session Additional Notes Both the Telnet user name and password are case se...

Страница 30: ...vel 1 0 Supported data types UByte UInt EXIT Exit the telnet session FACTORYFWIMAGE Reset unit to factory firmware image and reboots the Module GET CONFIG Display the current connection settings Examp...

Страница 31: ...192 168 21 101 Subnet Mask 255 255 255 0 Gateway IP 192 168 21 2 MAC Address 00 60 9f 90 0d 39 GET LOCATION Displays the location parameter for NDP set by the SET LOCATION command on page 27 GET SN Re...

Страница 32: ...nection settings interactively allowing the user to specify the mode If mode is TCP or UDP the master URL and port number can be specified as well If AUTO is selected the System number can be specifie...

Страница 33: ...ve entered Domain Name amx com DNS Entry 1 192 168 20 5 DNS Entry 2 12 18 110 8 DNS Entry 3 12 18 110 7 Is this correct Type Y or N and Enter Y Settings written Device must be rebooted to enable new s...

Страница 34: ...IP Addressing Modes DHCP and Static IP section on page 10 for details SET LOCATION Sets the location parameter for NDP Syntax SET LOCATION location Maximum length 25 characters If the name entered exc...

Страница 35: ...a carriage return If an ALT 255 is entered two 255 characters are sent per the Telnet RAFT If the code to go back to command mode is entered ALT 29 which is the character is not sent but Telnet comman...

Страница 36: ...Programming Ethernet Keypads 29 Instruction Manual Novara Ethernet Keypads...

Страница 37: ...egistered trademarks of AMX AMX reserves the right to alter specifications without notice at any time It s Your World Take Control 3000 RESEARCH DRIVE RICHARDSON TX 75082 USA 800 222 0193 469 624 8000...

Отзывы: