Configuring Communications
30
MVP-8400i 8.4" Modero® ViewPoint® Touch Panel with Intercom
3.
Click the
Communications Settings
button to open the
Communications Settings
dialog.
4.
Click the
NetLinx Master
radio button (
from the Platform Selection section
).
5.
Click the
Virtual Master
radio button (
from the Transport Connection Option section
).
6.
Click the
Edit Settings
button to open the
Virtual NetLinx Master Settings
dialog (FIG. 27).
7.
Enter the System number (default is
1
).
8.
Click
OK
to close all open dialogs and save your settings.
9.
Click the
OnLine Tree
tab in the Workspace window to view the devices on the Virtual System.
10.
Right-click on
Empty Device Tree/System
and select
Refresh System
to re-populate the list.
The panel will not appear as a device below the virtual system number (in the Online Tree tab)
until both the system number (default = 1) is entered into the Master Connection section of the
System Settings page and the panel is restarted.
The Connection status turns green after a few seconds to indicate an active USB connection to
the PC (Virtual Master).
If the System Connection icon does not turn green, check the USP connection and
communication settings and refresh the system.
Ethernet
1.
When using
Ethernet
, press the listed
Mode
to toggle through the available connection modes:
2.
Select the
Master Port Number
to open the keypad and change this value. The default setting for the
port is
1319
.
3.
Set your Master Port and select
Done
.
If you have enabled password security on your master you need to set the username and password within
the device.
4.
Select the blank field
Username
to open the keyboard.
5.
Set your Username and select
Done
.
6.
Select the blank field
Password
to open the keyboard.
7.
Set your Password and select
Done
.
8.
Press the
Back
button to return to the
Protected Setup
page.
9.
Press the
Reboot
button to reboot device and confirm changes.
Connection Modes
Mode Description
Procedures
Auto
The device connects to the first master that
responds. This setting requires you set the
System Number.
Setting the System Number:
1. Select the
System Number
to open the keypad.
2. Set your System Number select
Done
.
URL
The device connects to the specific IP of a
master via a TCP connection. This setting
requires you set the Master’s IP.
Setting the Master IP:
1. Select the
Master IP
number to the keyboard.
2. Set your Master IP and select
Done
.
Listen
The device "listens" for the master to initiate
contact. This setting requires you provide the
master with the device’s IP.
Confirm device IP is on the Master URL list. You
can set the Host Name on the device and use it to
locate the device on the master. Host Name is
particularly useful in the DHCP scenario where the
IP address can change.
Содержание Modero ViewPoint MVP-8400i
Страница 24: ...NXA CFSP Compact Flash 10 MVP 8400i 8 4 Modero ViewPoint Touch Panel with Intercom ...
Страница 52: ...Configuring Communications 38 MVP 8400i 8 4 Modero ViewPoint Touch Panel with Intercom ...
Страница 112: ...EAP Security Server Certificates 98 MVP 8400i 8 4 Modero ViewPoint Touch Panel with Intercom ...
Страница 188: ...Programming 174 MVP 8400i 8 4 Modero ViewPoint Touch Panel with Intercom ...
Страница 194: ...Appendix A Text Formatting 180 MVP 8400i 8 4 Modero ViewPoint Touch Panel with Intercom ...
Страница 212: ...Appendix C Troubleshooting 198 MVP 8400i 8 4 Modero ViewPoint Touch Panel with Intercom ...