
Setup Pages
59
MVP Modero ViewPoint Touch Panels
The elements of this page include:
Refer to the
Step 3: Choose a Master Connection Mode
section on page 31 for more detailed information
on using the System Settings page.
System Settings Page Elements
Back:
Saves all changes and returns to the previous page.
Connection Status icon:
The icon in the upper-right corner of each Setup page shows online/offline state
of the panel to the master.
• Bright red - disconnected
• Bright green - connected. Blinks when a blink message is received to dark
green every 5 seconds for half a second then go back to bright green.
• Bright yellow - panel missed a blink message from the master. It will remain
yellow for 3 missed blink messages and then turn red. It will return to green
when a blink message is received.
Note
: a Lock appears on the icon if the panel is connected to a secured NetLinx
Master.
Master Connection:
Sets the NetLinx Master communication values:
Type
Sets the NetLinx Master to communicate with the panel via either USB or
Ethernet. This is based on the cable connection from the rear.
Note
: ICSNet is not a supported option on this panel.
•
Ethernet
is a CAT-5 cable (10/100Base T terminated in an RJ-45 connector)
used to network computers together and is used in most LAN (local area
networks). This description is also used to refer to both wired and wireless
communication.
•
USB
option cannot be used on Modero panels which are not equipped with a
rear USB port.
Master Connection (Cont.):
Mode
Cycles between the connection modes: URL, Listen, and Auto.
(Ethernet Only - disabled when USB is selected)
•
URL
- In this mode, enter the IP/URL, Master Port Number, and username/
password (if used) on the Master. The System Number field is read-only - the
panel obtains this information from the Master.
•
Listen
- In this mode, add the panel address into the URL List in NetLinx
Studio and set the connection mode to Listen. This mode allows the Modero
touch panel to “listen” for the Master’s communication signals. The System
Number and Master IP/URL fields are read-only.
•
Auto
- In this mode, enter the System Number and a username/password (if
applicable). Use this mode when both the panel and the NetLinx Master are
on the same Subnet, and the Master has its UDP feature enabled. The
Master IP/URL field is read-only.
System Number
Allows you to enter a system number. Default value is 0 (zero).
(ETHERNET Only - disabled when USB is selected)
Master IP/URL
Sets the Master IP or URL of the NetLinx Master.
(ETHERNET Only - disabled when USB is selected)
Master Port Number
Allows you to enter the port number used with the NetLinx Master.
• Default = 1319
(ETHERNET Only - disabled when USB is selected)
Username/Password
If the target Master has been previously secured, enter the alpha-numeric string
(into each field) assigned to a pre-configured user profile on the Master. This
profile should have the pre-defined level of access/configuration rights.
Содержание Modero ViewPoint MVP-7500
Страница 4: ......
Страница 10: ...vi MVP 7500 8400 Modero Viewpoint Wireless Touch Panels Table of Contents ...
Страница 20: ...NXA CFSP Compact Flash 10 MVP 7500 8400 Modero Viewpoint Wireless Touch Panels ...
Страница 182: ...Programming 172 MVP 7500 8400 Modero Viewpoint Wireless Touch Panels ...
Страница 186: ...Panel Calibration 176 MVP 7500 8400 Modero Viewpoint Wireless Touch Panels ...
Страница 192: ...Appendix A Text Formatting 182 MVP 7500 8400 Modero Viewpoint Wireless Touch Panels ...
Страница 203: ...Appendix B Wireless Technology 193 MVP 7500 8400 Modero Viewpoint Wireless Touch Panels ...
Страница 204: ...Appendix B Wireless Technology 194 MVP 7500 8400 Modero Viewpoint Wireless Touch Panels ...
Страница 208: ...Appendix C Troubleshooting 198 MVP 7500 8400 Modero Viewpoint Wireless Touch Panels ...
Страница 209: ...Appendix C Troubleshooting 199 MVP 7500 8400 Modero Viewpoint Wireless Touch Panels ...