Protected Setup Pages
58
MVP-5100/5150 5.2" Modero Viewpoint Touch Panels
System Settings Page
The
System Settings
page (FIG. 50) displays sets the NetLinx Master’s communication settings.
The elements of this page include:
FIG. 50
System Settings page
System Settings Page Elements
Back:
Saves all changes and returns to the previous page.
WiFi/Wired/USB Icon:
The icon to the left of the Connection Status Icon displays whether the current
connection to the Master is
Wireless
(image of a radio antenna),
Wired
(image
of three networked computers), or
USB
(USB connection symbol).
Connection Status icon:
The icon in the upper-right corner of each Protected Setup page provides a
constant visual indication of current connection status.
Note
: a Lock appears on the icon if the panel is connected to a secured NetLinx
Master.
Master Connection:
Sets the NetLinx Master communication values.
Type:
Displays how the panel is connected to the Master. The connection may be
Wireless
(wireless connection) or
Any
(no connection). This field cannot be
changed.
Mode:
Cycles between the connection modes:
URL
,
Listen
, and
Auto
.
•
Auto
- In this mode, enter the System Number and a username/password (if
applicable). Use this mode when both the panel and the NetLinx Master are
on the same Subnet and the Master has its UDP feature enabled. The Master
IP/URL field is read-only.
•
URL
- In this mode, enter the IP/URL, Master Port Number, and username/
password (if used) on the Master. The System Number field is read-only - the
panel obtains this information from the Master.
•
Listen
- In this mode, add the panel address into the URL List in NetLinx
Studio and set the connection mode to Listen. This mode allows the Modero
touch panel to “listen” for the Master’s communication signals. The System
Number and Master IP/URL fields are read-only.
System Number:
Allows entry of a system number. Default value is 0 (zero).
Master IP/URL:
Sets the Master IP or URL of the NetLinx Master.
Master Port Number:
Allows entry of the port number used with the NetLinx Master. Default = 1319
Username/Password:
If the target Master has been previously secured, enter the alpha-numeric string
(into each field) assigned to a pre-configured user profile on the Master. This
profile should have the pre-defined level of access/configuration rights.
USB IP Settings:
A
USB
connection is a direct connection from the panel’s mini-USB port to a
corresponding USB port on the PC (acting as a Virtual Master). Press either of
the fields to open the
IP Address
and
Subnet Mask
keypads.
Содержание Modero ViewPoint MVP-5100
Страница 4: ......
Страница 12: ...viii Document Name Here Table of Contents ...
Страница 22: ...Introduction 10 MVP 5100 5150 5 2 Modero Viewpoint Touch Panels ...
Страница 34: ...Accessories 22 MVP 5100 5150 5 2 Modero Viewpoint Touch Panels ...
Страница 100: ...Protected Setup Pages 88 MVP 5100 5150 5 2 Modero Viewpoint Touch Panels ...
Страница 114: ...Upgrading Firmware 102 MVP 5100 5150 5 2 Modero Viewpoint Touch Panels ...
Страница 160: ...Programming 148 MVP 5100 5150 5 2 Modero Viewpoint Touch Panels ...
Страница 168: ...Battery Life and Replacement 156 MVP 5100 5150 5 2 Modero Viewpoint Touch Panels ...
Страница 176: ...Appendix A Text Formatting 164 MVP 5100 5150 5 2 Modero Viewpoint Touch Panels ...
Страница 184: ...Appendix B Wireless Technology 172 MVP 5100 5150 5 2 Modero Viewpoint Touch Panels ...
Страница 188: ...Appendix C Troubleshooting 176 MVP 5100 5150 5 2 Modero Viewpoint Touch Panels ...
Страница 189: ...Appendix 177 MVP 5100 5150 Modero Viewpoint Touch Panels ...