40
MVP-5100/5150 5.2" Modero Viewpoint Touch Panels
Connecting to the NetLinx Master via Ethernet (MVP-5150 Only)
1.
When using Wireless Ethernet with the MVP-5150, press the listed
Mode
to toggle through the
available connection modes:
2.
Select the
Master Port Number
to open the keypad and change this value. The default setting for the
port is
1319
.
3.
Set the Master Port and select
Done
.
4.
If you enabled password security on your Master, set the username and password within the device.
5.
Select the blank field
Username
to open the keyboard.
6.
Set the Username and select
Done
.
7.
Select the blank field
Password
to open the keyboard.
8.
Set the Password and select
Done
.
9.
Press the
Back
button to return to the
Protected Setup
page.
Connection Modes
Mode Description
Procedures
None
No connection
None
Auto
The device connects to the first master that
responds. This setting requires setting the
System Number.
Setting the System Number:
1. Select the
System Number
to open the keypad.
2. Set your System Number and select
Done
.
URL
The device connects to the specific IP of a
Master via a TCP connection. This setting
requires setting the Master’s IP.
Setting the Master IP:
1. Select the
Master IP
number to the keyboard.
2. Set the Master IP and select
Done
.
Listen
The device "listens" for the Master to initiate
contact. This setting requires providing the
Master with the device’s IP.
Confirm that the device IP is on the Master URL
list. Set the Host Name on the device and use it to
locate the device on the Master. Host Name is
particularly useful in the DHCP scenario, where
the IP address can change.
Содержание Modero ViewPoint MVP-5100
Страница 4: ......
Страница 12: ...viii Document Name Here Table of Contents ...
Страница 22: ...Introduction 10 MVP 5100 5150 5 2 Modero Viewpoint Touch Panels ...
Страница 34: ...Accessories 22 MVP 5100 5150 5 2 Modero Viewpoint Touch Panels ...
Страница 100: ...Protected Setup Pages 88 MVP 5100 5150 5 2 Modero Viewpoint Touch Panels ...
Страница 114: ...Upgrading Firmware 102 MVP 5100 5150 5 2 Modero Viewpoint Touch Panels ...
Страница 160: ...Programming 148 MVP 5100 5150 5 2 Modero Viewpoint Touch Panels ...
Страница 168: ...Battery Life and Replacement 156 MVP 5100 5150 5 2 Modero Viewpoint Touch Panels ...
Страница 176: ...Appendix A Text Formatting 164 MVP 5100 5150 5 2 Modero Viewpoint Touch Panels ...
Страница 184: ...Appendix B Wireless Technology 172 MVP 5100 5150 5 2 Modero Viewpoint Touch Panels ...
Страница 188: ...Appendix C Troubleshooting 176 MVP 5100 5150 5 2 Modero Viewpoint Touch Panels ...
Страница 189: ...Appendix 177 MVP 5100 5150 Modero Viewpoint Touch Panels ...