Configuring Communication
33
MVP-5100/5150 5.2" Modero Viewpoint Touch Panels
8.
If entering a Current Key generated either by the target AP or another Modero panel
, within
the
WEP Keys
section, touch the
Key #
button to launch the
WEP Key #
keyboard (FIG. 21), enter
the characters and press
Don
e when finished.
This Key value corresponds to the Default WEP Key number used on the Access Point and
selected in the
Default Key
field.
9.
The remaining
Current Key
field is greyed-out and cannot be altered by the user. The
Authentication
button can be toggled between
Open
and
Shared
.
10.
Click
Save
to save your changes and return to the
Wireless Settings
page.
11.
Verify that the fields within the
IP Settings
section have been properly configured. Refer to
Step 1:
Configure the Device’s Wireless IP Settings (MVP-5150 Only)
section on page 26 for detailed
information.
12.
Press the
Back
button to navigate to the
Protected Setup
page and press the on-screen
Reboot
button to save any changes and restart the panel. Remember that you will need to navigate to the
System Settings
page and configure the connection to a target Master.
13.
After the panel restarts, return to the
Wireless Settings
page to verify the Signal Level Value and
Signal Level.
Configuring multiple wireless touch panels to communicate to a target AP
1.
For each communicating touch panel, complete all of the steps outlined within the
previous
Automatically Setting SSID
section on page 31.
2.
Navigate back to the
Wireless Settings
page on each panel.
3.
Verify that all communicating Modero panels are using the same
SSID
,
encryption level
,
Default
Key #
, and an identical
Current Key value
.
As an example, all panels should be set to Default Key
#1
and be using
aa:bb:cc:dd:ee
as the
Current Key string value. This same Key value and Current Key string should be used on the
target AP.
4.
Repeat steps 1 - 3 on each panel.
FIG. 21
WEP Key # Keyboard
The Signal Level bar provides some information regarding the strength of the
connection to a Access Point. Configuration of the network could be required if there
is no signal or no IP Address is displayed.
Содержание Modero ViewPoint MVP-5100
Страница 4: ......
Страница 12: ...viii Document Name Here Table of Contents ...
Страница 22: ...Introduction 10 MVP 5100 5150 5 2 Modero Viewpoint Touch Panels ...
Страница 34: ...Accessories 22 MVP 5100 5150 5 2 Modero Viewpoint Touch Panels ...
Страница 100: ...Protected Setup Pages 88 MVP 5100 5150 5 2 Modero Viewpoint Touch Panels ...
Страница 114: ...Upgrading Firmware 102 MVP 5100 5150 5 2 Modero Viewpoint Touch Panels ...
Страница 160: ...Programming 148 MVP 5100 5150 5 2 Modero Viewpoint Touch Panels ...
Страница 168: ...Battery Life and Replacement 156 MVP 5100 5150 5 2 Modero Viewpoint Touch Panels ...
Страница 176: ...Appendix A Text Formatting 164 MVP 5100 5150 5 2 Modero Viewpoint Touch Panels ...
Страница 184: ...Appendix B Wireless Technology 172 MVP 5100 5150 5 2 Modero Viewpoint Touch Panels ...
Страница 188: ...Appendix C Troubleshooting 176 MVP 5100 5150 5 2 Modero Viewpoint Touch Panels ...
Страница 189: ...Appendix 177 MVP 5100 5150 Modero Viewpoint Touch Panels ...