Device Setup Pages
12
Mio Modero R-4
Changing the remote timeout
By default, the Mio R-4 will go to sleep at the same time as the selected display timeout if the device is
not already in its charging cradle. By disabling this default, the device remains connected to the rest of
the ZigBee network while the device is otherwise asleep, and allows a faster response when picked up
again. In this mode, the button backlight and the touchscreen turn themselves off after the
Display
Timeout
time is reached, but the remote remains online until after the set
Sleep Timeout
is reached. After
this point, the device will reconnect to the network, but this reconnection will be much faster than if the
device were shut off.
1.
Select
Remote & Display Settings
from the Setup Page.
2.
Under
Display Timeout
, use the Up/Down arrows to adjust the timeout period in five-second
increments, to a maximum of 30 seconds.
3.
Under
Sleep Timeout
, use the Up/Down arrows to adjust the timeout period in regular increments, to
a maximum of 240 minutes.
4.
To disable the default setting and allow separate display and sleep timeouts, press the
Sleep on
Display Timeout
button. When
Sleep on Display Timeout
is engaged, the button is green (FIG. 7),
and the
Sleep Timeout
settings will be greyed out. Press the button again to re-enable the
Sleep on
Display Timeout
function..
Remote & Display Settings (Cont.)
High Port
The highest port number specified in the project pages.
High Address
The highest address specified in the project pages.
High Channel
The highest channel specified in the project pages.
High Level
The highest level specified in the project pages
Refresh Rate
The refresh rate, in screen lines, of the Setup page screen display.
Screen Width
The width (in pixels) of the Setup page screen display.
Screen Height
The height (in pixels) of the Setup page screen display.
Blink Rate
The rate (in seconds) at which features on the screen will blink.
Wake-up String
The code string chosen by the NetLinx administrator for the unit wake-up.
Sleep String
The code string chosen by the NetLinx administrator for the unit sleep mode.
Start-up String
The code string chosen by the NetLinx administrator for the unit startup.
The Sleep Timeout period increments are 0 (sleep timeout disabled, remote will stay
active until the battery charge runs low), 3, 5, 10, 15, 30, 60, 120, 180, and 240
minutes.