Perform these steps to program a device:
1.
Open the Device Configuration & Layout Inspector window (see page 27).
2.
Tag any devices you want to program. You can tag as many devices as needed.
3.
On the AMX DCS window, build a script using the device interface and the available options.
4.
Click
Program Devices
. The
Programming Device(s) Monitor
dialog opens and displays the list of devices to be
programmed. AMX DCS begins programming the device immediately.
All devices are programmed in parallel. The options at the bottom of the dialog are disabled until the updates are
complete. A confirmation box appears if all updates are successful. If any updates fail, click
Re-Program
Unsuccessful
to attempt the update again.
Device Library Manager
The Device Library Manager (FIG. 75) enables you to add, import, and modify information about individual devices you
can configure with DCS software. You can modify the device's serial connection settings and provide hexadecimal
values, where needed, for executable and status commands. The Device Library Manager is accessible by selecting
Device Library Manager from the File menu on the AMX DCS window.
If you open a device with a script already programmed or working, but you just want
to set the button setup (backlight) color, you must also re-program the script. Failure
to program the script again may result in the device rebooting, and programming the
device configuration without the new button setup being transmitted to the device.
FIG. 75
Device Library Manager
You can command Novara ControlPads to match only a piece of the response that
comes back from a device. This ability is useful in cases where a device may send
multiple responses back at one time, or may put other variable data before/after the
RS-232 responses. This option is not available for the AVX-400. Since DCS is shared
between the AVX-400 and the Novara ControlPads, if you modify your device library
entry to use this method of partial matching, you will not get a match on the AVX-400,
and will not see any values or changes to values you are monitoring.
Содержание CP-3006
Страница 6: ...iv Novara 3000 Series ControlPads Instruction Manual Table of Contents ...
Страница 30: ...Button Labeling 24 Novara 3000 Series ControlPads Instruction Manual ...
Страница 68: ...Device Configuration Software 62 Novara 3000 Series ControlPads Instruction Manual ...
Страница 75: ...RMS Configuration 69 Novara 3000 Series ControlPads Instruction Manual ...