Wiring and Device Connections
15
Novara 3000 Series ControlPads Instruction Manual
Resetting the ControlPad
Each ControlPad features a pinhole Reset pushbutton on the rear on the unit for factory reset. To reset the ControlPad,
press and hold in the Reset pushbutton for 10 seconds, then release it. The ControlPad will reset. During factory reset,
the backlight turns off for all buttons, but all buttons should be back online after 1-2 minutes. If you do not hold in the
reset button for the full 10 seconds, the reset does not occur. (There is no soft reboot with the Reset button, but you can
perform a soft reboot from the web pages.)
CP-RC01 IR Remote
The CP-RC01 IR Remote (FG1302-70) (FIG. 1) provides local control of CP-3008 and CP-3017 series ControlPads.
Product Specifications
When you reset a ControlPad, the ControlPad is restored to the factory default, so
you will lose any scripts, IRL files, Device Interrogation settings, or RMS server
information loaded on the system.
FIG. 20
CP-RC01 IR Remote
CP-RC01 IR Remote
Dimensions (HWD):
8” x 2” x 1” (20 cm x 5.5 cm x 2.8 cm)
Weight:
Without batteries: 0.208 lbs (94.34g)
Battery:
2 AAA Batteries
Power Consumption:
Approximately 50mA at IR transmit
IR Transmit Frequency:
38 KHz
Range:
20-30ft (6-9m) Standard
Note:
Range can be affected by factors such as angle of incidence and LED graph brightness.
Operating Environment:
• Storage temperature range: -40° - 158° F (-40° - 70° C)
• Operating temperature range: 41° - 104° F (5° - 40° C)
• Relative humidity: 10% to 90%, non-condensing
Содержание CP-3006
Страница 6: ...iv Novara 3000 Series ControlPads Instruction Manual Table of Contents ...
Страница 30: ...Button Labeling 24 Novara 3000 Series ControlPads Instruction Manual ...
Страница 68: ...Device Configuration Software 62 Novara 3000 Series ControlPads Instruction Manual ...
Страница 75: ...RMS Configuration 69 Novara 3000 Series ControlPads Instruction Manual ...