Device Configuration Software
44
Novara 3000 Series ControlPads Instruction Manual
5.
Click
Load Devices
to close the dialog and return to the AMX DCS window. You should now see the Device Model
and Function menus populated with one or more options.
6.
Select a device model from the
Device Model
options menu.
7.
Select a function from the
Functions
menu.
8.
Select the number of times you want the function to occur from the Action menu. If you choose
Select Send No.
, do
the following:
Use the
No. of Transmission Strings
slider to indicate the number of times you want the function to transmit.
Use the
Delay Time between Strings
slider to indicate the amount of time in between each occurrence of the
function.
9.
Select the RS232 port the device is connected to from the Port options menu.
10.
In the Scripting area, click
Add
. The RS232 event now appears in the script.
IR
The IR option configures an IR device for the keypad. IR devices connect to the IR ports on the rear of the keypad.
The following table lists the IR options:
Perform these steps to add an IR event to a script:
1.
In the AMX DCS window, click
IR
. The IR options appear (FIG. 57).
If the Make and Type fields are blank, you need to use the Device Library Manager to
create or import devices. See the Adding a Device to the Device Library
section on
page 56
and the Importing a Device Library
section on page 57
for more information.
FIG. 57
IR options
IR Options
Port
Enables you to select the port on the ControlPad you want to use to execute the function. The
number of ports available varies depending on the type of ControlPad you are using.
Carrier
Enables you to turn on the carrier. When hard-wiring to a device, the carrier may have to be
turned off. Otherwise, carrier must be left On.
Function Code - Name Enables you to select a function code for the device to perform.
Action
Enables you to select the number of times you want the function to execute. You can choose
from IR Pulse and IR Duration.
Transmitter Duration
Use the slider arrows to indicate the amount of time, in milliseconds, you want a function to
transmit. You can set any amount between 10 and 2000. This option is only available if you
select IR Duration from the Action menu.
Note:
If you set the Transmission Duration slider to a value in milliseconds, which is less than
the full pulse length of the IRL file's recorded pulse, the ControlPad sends at least 1 full pulse
when the script is triggered. Fractional IR pulses are not supported.
Additionally, if you set the value to a number greater than the length of the pulse, the ControlPad
sends as many pulses as possible that fit into the time frame. No fractional pulses are sent.
Device Information
Displays the Make, Model, and HandControl Name of the IR device, as well as any additional
information in the Note area. This information is view-only.
Load IR File
Click to load an AMX IR file (.irl) containing information about your IR device. You must load an
.irl file for each port.
Clear IR File
Click to clear the loaded IR file (.irl) for the port.
Содержание CP-3006
Страница 6: ...iv Novara 3000 Series ControlPads Instruction Manual Table of Contents ...
Страница 30: ...Button Labeling 24 Novara 3000 Series ControlPads Instruction Manual ...
Страница 68: ...Device Configuration Software 62 Novara 3000 Series ControlPads Instruction Manual ...
Страница 75: ...RMS Configuration 69 Novara 3000 Series ControlPads Instruction Manual ...